Lenovo ThinkSystem SR635 Server

Product Guide

Home
Top

Abstract

The Lenovo ThinkSystem SR635 is a 1-socket 1U server that features the AMD EPYC 7002 "Rome" and AMD EPYC 7003 "Milan" families of processors. With up to 64 cores per processor and support for the PCIe 4.0 standard for I/O, the SR635 offers the ultimate in single-socket server performance in a space-saving 1U form factor.

This product guide provides essential pre-sales information to understand the ThinkSystem SR635 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR635 and consider its use in IT solutions.

Change History

Changes in the March 6, 2024 update:

  • The following preconfigured models for customers in North America are now withdrawn:
    • 7Y99A039NA, 7Y99A038NA

Changes in the March 5, 2024 update:

  • Added the following drive - Internal drive options section:
    • ThinkSystem 2.5" PM893a 7.68TB Read Intensive SATA 6Gb HS SSD, 4XB7A87528

Walkthrough video with David Watts and Russ Resnick

Introduction

The Lenovo ThinkSystem SR635 is a 1-socket 1U server that features the AMD EPYC 7002 "Rome" and AMD EPYC 7003 "Milan" families of processors. With up to 64 cores per processor and support for the PCIe 4.0 standard for I/O, the SR635 offers the ultimate in single-socket server performance in a space-saving 1U form factor. With up to 128 PCIe lanes, the server is ideal for dense workloads that can take advantage of GPU processing and high-performance NVMe drives.

Suggested uses: AI Inference, VDI, OLTP, Analytics, HPC, software-defined storage

Lenovo ThinkSystem SR635
Figure 1. Lenovo ThinkSystem SR635

Did you know?

By using a high-performance server with only one processor installed, you can take advantage of lower software costs when the software licensing is using a per-socket model. In addition, The server offers onboard NVMe PCIe ports that allow direct connections to 16x NVMe SSDs, which frees up I/O slots and helps lower NVMe solution acquisition costs.

The SR635 has been designed to take advantage of the features of the EPYC 7002 and 7003 processors, such as the full performance of 280W 64-core processors, support for 3200 MHz memory and PCIe Gen 4.0 support. Competitive servers that are based on the older EPYC 7001 "Naples" designs may not be able to offer these performance features.

Key features

Combining performance and flexibility, the SR635 server is a great choice for enterprises of all sizes. The server offers a broad selection of drive and slot configurations and offers high performance features that industries such as finance, healthcare and telco need. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design can improve your business environment and can help save operational costs.

Scalability and performance

The SR635 offers numerous features to boost performance, improve scalability and reduce costs: 

  • Supports the AMD EPYC 7002 and EPYC 7003 families family of processors
  • Supports processors with up to 64 cores and 128 threads, core speeds of up to 4.1 GHz, and TDP ratings of up to 280W.
  • Support for up to 16 TruDDR4 memory DIMMs, with 8 memory channels and 2 DIMMs per channel. With 1 DIMM installed per channel (8 DIMMs total), memory operates at up to 3200 MHz. With 2 DIMMs per channel (16 DIMMs total), memory operating at up to 2933 MHz.
  • Using 128GB DIMMs, the server supports up to 2TB of system memory.
  • Supports up to three single-width GPUs, each up to 75W. A 3:1 ratio of GPUs to CPUs means substantial processing power is available with just one CPU.
  • Supports up to 16x 2.5-inch hot-swap drive bays, by using combinations of front-accessible (up to 10 bays), mid-accessible (4 bays), and rear-accessible (2 bays).
  • Supports four 3.5-inch drive bays for lower-cost high-capacity storage. 2.5-inch and 3.5-inch drive bays can be mixed in several combinations.
  • Supports 16x NVMe drives without oversubscription of PCIe lanes (1:1 connectivity) and without the need for additional NVMe adapters. The use of NVMe drives maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
  • Supports 12x SATA drives using the onboard SATA controller (no additional adapter needed), enabling lower cost, high capacity storage solution for cold storage workloads.
  • Supports 12x SAS drives using a variety of support RAID controllers or SAS HBAs.
  • Supports high-speed RAID controllers from Broadcom providing 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache and support for 16 drives on a single controller.
  • Supports M.2 drives for convenient operating system boot functions or data storage. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for performance and reliability.
  • The server has a dedicated industry-standard OCP 3.0 small form factor (SFF) slot, with a PCIe 4.0 x16 interface, supporting a variety of Ethernet network adapters. Simple-swap mechanism with thumbscrews and pull-tab enables tool-less installation and removal of the adapter. Supports shared BMC network sideband connectivity to enable out-of-band systems management.
  • The server offers PCI Express 4.0 I/O expansion capabilities that doubles the theoretical maximum bandwidth of PCIe 3.0 (16GT/s in each direction for PCIe 4.0, compared to 8 GT/s with PCIe 3.0). A PCIe 4.0 x16 slot provides 64 GB/s bandwidth, enough to support a 400GbE network connection.
  • A total of up to four PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter) plus a slot dedicated to the OCP adapter.

Availability and serviceability

The SR635 provides many features to simplify serviceability and increase system uptime:

  • The server uses ECC memory and supports memory RAS features including Single Device Data Correction (SDDC, also known as Chipkill), Patrol/Demand Scrubbing, DRAM Address Command Parity with Replay, and DRAM Uncorrected ECC Error Retry.
  • The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
  • The M.2 SATA RAID Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
  • The server has up to two hot-swap redundant power supplies and seven hot-swap redundant fans to provide availability for business-critical applications.
  • The power-source-independent light path diagnostics uses LEDs to lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • Solid-state drives (SSDs) offer more reliability than traditional mechanical HDDs for greater uptime.
  • The built-in ASPEED AST2500 baseboard management controller (BMC) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Proactive Platform Alerts: Voltage regulators, memory, fans, power supplies, server ambient and subcomponent temperatures. Alerts can be surfaced through the BMC to managers such as Lenovo XClarity Administrator. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • Web-based ThinkSystem System Manager (TSM) provides remote access to the BMC for remote management.
  • Lenovo XClarity Provisioning Manager Lite (LXPM Lite) tool can be used to install an operating system on the server and perform system diagnostics.
  • Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

Systems management features simplify local and remote management of the SR635:

  • Supports Lenovo XClarity Provisioning Manager Lite (LXPM Lite) for system setup and firmware upgrades.
  • An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Support for industry standard management protocols, IPMI 2.0, SNMP 3.0, Redfish REST API, serial console via IPMI
  • An integrated hardware Trusted Platform Module (TPM) supporting TPM 2.0 enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Administrator and power-on passwords help protect from unauthorized access to the server.
  • Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and integrates with Redfish-based applications to provide automated controls to lower energy costs.
  • Supports AMD Secure Root-of-Trust, Secure Run and Secure Move features to minimize potential attacks and protect data as the OS is booted, as applications are run and as applications are migrated from server to server.
  • Supports Secure Boot to ensure only a digitally signed operating system can be used.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.

Energy efficiency

The SR635 offers the following energy-efficiency features to save energy, reduce operational costs, and increase energy availability:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications
  • Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
  • Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system and thus keeping your system cooler.
  • Optional Lenovo XClarity Energy Manager provides advanced data center power notification and analysis to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the server.

Front view of the Lenovo ThinkSystem SR635
Figure 2. Front view of the Lenovo ThinkSystem SR635

The following figure shows the components visible from the rear of the server. As shown, there are three different configurations available

Rear view of the Lenovo ThinkSystem SR635
Figure 3. Rear view of the Lenovo ThinkSystem SR635

The following figure shows the locations of key components inside the server.

Internal view of the Lenovo ThinkSystem SR635
Figure 4. Internal view of the Lenovo ThinkSystem SR635

System architecture

The following figure shows the architectural block diagram of the SR635, showing the major components and their connections.

SR635 system architectural block diagram
Figure 5. SR635 system architectural block diagram

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
Components Specification
Machine types 7Y98 - 1 year warranty
7Y99 - 3 year warranty
Form factor 1U rack.
Processor One AMD EPYC 7002 Series processor (formerly codenamed "Rome") or AMD EPYC 7003 Series processors (formerly codenamed "Milan"). Supports processors up to 64 cores, core speeds of up to 4.1 GHz, and TDP ratings of up to 280W.
Memory 16 DIMM slots. The processor has 8 memory channels, with 2 DIMMs per channel. Lenovo TruDDR4 RDIMMs are supported. DIMMs are available in two speeds: 3200 MHz and 2933 MHz. With 3200 MHz memory, the server supports a 3200 MHz memory bus speed at 1 DIMM per channel (DPC) and 2933 MHz at 2 DPC. With 2933 MHz memory, the server supports a 2933 MHz memory bus speed at both 1 and 2 DPC.
Memory maximum Up to 2TB with 16x 128GB 3DS RDIMMs
Persistent memory Not supported.
Memory protection ECC, SDDC, Patrol/Demand Scrubbing, DRAM Address Command Parity with Replay, DRAM Uncorrected ECC Error Retry, Post Package Repair
Disk drive bays

Up to 4x 3.5-inch or 16x 2.5-inch hot-swap drive bays:

  • Front bays can be one of the following:
    • 4x 3.5-inch hot-swap SAS/SATA
    • 8x 2.5-inch hot-swap SAS/SATA
    • 6x 2.5-inch hot-swap SAS/SATA + 4x 2.5-inch hot-swap AnyBay
    • 10x 2.5-inch hot-swap AnyBay
  • Mid (internal): 4x 2.5-inch hot-swap NVMe bays
  • Rear can be one of the following:
    • 2x 2.5-inch hot-swap SAS/SATA bays
    • 2x 2.5-inch hot-swap NVMe bays

See Supported drive bay combinations for details. AnyBay bays support SAS, SATA or NVMe drives. NVMe bays only support NVMe drives. Both mid and rear drive bays can be used in conjunction with 2.5-inch front drive bays. Mid bays are hot-swap drive bays and are accessible by removing the top cover of the server. The server supports up to 16x NVMe drives (10 front, 4 mid, 2 rear) all with direct connections (no oversubscription).

Maximum internal storage
  • 2.5-inch drives:
    • 368.64TB using 12x 30.72TB 2.5-inch SAS/SATA SSDs
    • 307.2TB using 10x 30.72TB 2.5-inch NVMe SSDs
    • 24TB using 12x 2TB 2.5-inch HDDs
  • 3.5-inch drives:
    • 88TB using 4x 22TB 3.5-inch HDDs
    • 61.44TB using 4x 15.36TB 3.5-inch SAS/SATA SSDs
Storage controller
  • Onboard SATA supporting up to 12 SATA drives (no RAID)
  • 12 Gb SAS/SATA RAID adapters
  • 12 Gb SAS/SATA non-RAID
Optical drive bays No internal optical drive.
Tape drive bays No internal backup drive.
Network interfaces Dedicated OCP 3.0 SFF slot with PCIe 4.0 x16 host interface. Supports a variety of 2-port and 4-port adapters with 1GbE, 10GbE and 25GbE network connectivity. One port can optionally be shared with the ASPEED management processor for Wake-on-LAN and NC-SI support.
PCI Expansion slots

A total of up to 4 PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter) plus a slot dedicated to the OCP adapter. Slot availability is based on riser selection.

Three choices for rear-access slots:

  • 3x PCIe 4.0 x16 low-profile slots
  • 1x PCIe 4.0 x16 full-height half-length slot + 1x PCIe 4.0 x16 low-profile slot
  • 1x PCIe 4.0 x16 low-profile slot (supports 2x rear 2.5-inch drive bays)

Optionally, an additional internal PCIe 4.0 x8 low-profile slot for al internal drive controller.

Ports

Front: Two USB 3.1 G1 (5 Gb/s) ports, optional VGA port.

Rear: USB 3.1 G1 (5 Gb/s) ports, one VGA video port, one DB-9 serial port, and one RJ-45 1GbE systems management port.

Internal: Optional M.2 module supporting up to two M.2 drives (for OS boot and drive storage support; not available in all configurations).

Cooling Six or seven N+1 redundant dual-rotor hot swap 40 mm fans, configuration dependent. One fan integrated in each power supply.
Power supply Up to two hot-swap redundant AC power supplies (all 80 PLUS Platinum certification): 550 W, 750 W, 1100 W and 1600 W AC options, supporting 220 V AC. 550 W, 750 W and 1100 W options also support 110V input supply. In China only, all power supply options support 240 V DC. Also available is a 1100W power supply with a -48V DC input.
Video Onboard graphics with 512 MB memory with 2D hardware accelerator, integrated into the ASPEED AST2500 BMC management processor. Maximum resolution is 1920x1200 at 60Hz, 32bpp
Hot-swap parts Drives, power supplies, and fans.
Systems management ASPEED AST2500 embedded management processor, XClarity Provisioning Manager Lite (LXPM Lite) for system setup and firmware upgrades. XClarity Administrator centralized infrastructure management, and XClarity Energy Manager centralized server power management. Light path diagnostics for local failure detection and reporting.
Security features Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 2.0. In China only, optional Nationz TPM 2.0. Optional lockable front security bezel. Optional chassis intrusion switch.
Operating systems supported Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics.
Limited warranty Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Width: 440 mm (17.3 in.), height: 43 mm (1.7 in.), depth: 755 mm (29.7 in.). See Physical and electrical specifications for details.
Weight Maximum: 19.2 kg (42.3 lb)

Models

ThinkSystem SR635 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR635 as listed in the columns in the following table:

  • General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
  • AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.

Preconfigured server models may also be available for the SR635, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.

The following table lists the base CTO models of the ThinkSystem SR635 server.

Table 2. Base CTO models
Machine Type/Model
General purpose
Machine Type/Model
for AI and HPC
Description
7Y99CTO1WW 7Y99CTOLWW ThinkSystem SR635 – 3-year warranty
7Y98CTO1WW 7Y98CTOLWW ThinkSystem SR635 – 1-year warranty

Models of the SR635 are defined based on whether the server has 2.5-inch drive bays at the front (called the 10x 2.5" chassis or simply the 2.5-inch chassis) or whether it has 3.5-inch drive bays at the front (called the 4x 3.5" chassis or simply the 3.5-inch chassis). For models, the feature codes for these chassis bases are as listed in the following table.

Table 3. Chassis base feature codes
Feature code Description
B5VL ThinkSystem SR635 10x2.5" Chassis
B5VM ThinkSystem SR635 4x3.5" Chassis

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Models for Australia and New Zealand

Table 4. Models for Australia and New Zealand
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
TopSeller models with a 3-year model (machine type 7Y99)
7Y99A029AU 7232P 8C 120W 3.1G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A02CAU 7232P 8C 120W 3.1G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A02JAU 7232P 8C 120W 3.1G 1x 16GB 3200 530-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Std Fric
7Y99A02KAU 7232P 8C 120W 3.1G 1x 16GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Fric
7Y99A02LAU 7252 8C 120W 3.1G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Fric
7Y99A02GAU 7262 8C 155W 3.2G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Fric
7Y99A02QAU 7262 8C 155W 3.2G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Std Fric
7Y99A02AAU 7282 16C 120W 2.4G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A02BAU 7282 16C 120W 2.4G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A02FAU 7282 16C 120W 2.4G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Fric
7Y99A02PAU 7282 16C 120W 2.4G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Std Fric
7Y99A00XAU 7302P 16C 155W 3.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Std Fric
7Y99A02EAU 7302P 16C 155W 3.0G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Fric
7Y99A02NAU 7302P 16C 155W 3.0G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Std Fric
7Y99A014AU 7402P 24C 180W 2.8G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A02HAU 7402P 24C 180W 2.8G 1x 32GB 3200 Onboard AHCI 8x 2.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Perf Fric
7Y99A02MAU 7402P 24C 180W 2.8G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Perf Fric
7Y99A00UAU 7502P 32C 180W 2.5G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A00WAU 7702P 64C 200W 2.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for South East Asian countries (ASEAN)

Table 5. Models for South East Asian countries (ASEAN)
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
TopSeller models with a 3-year model (machine type 7Y99)
7Y99A00VSG 7302P 16C 155W 3.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Std Fric
7Y99A00QSG 7402P 24C 180W 2.8G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A00YSG 7502P 32C 180W 2.5G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A00RSG 7702P 64C 200W 2.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for Brazil

Table 6. Models for Brazil
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
Standard models with a 3-year model (machine type 7Y99)
7Y99A01GBR 7262 8C 155W 3.2G 1x 16GB 2933 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01HBR 7302P 16C 155W 3.0G 1x 16GB 2933 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01JBR 7302P 16C 155W 3.0G 1x 32GB 2933 730-8i 1GB 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01FBR 7402P 24C 180W 2.8G 1x 32GB 2933 730-8i 1GB 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 1100W HS (Y) Yes 6x Perf Slide

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for EMEA countries

Table 7. Models for EMEA countries
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
Standard models with a 3-year model (machine type 7Y99)
Models with third-generation AMD EPYC processors
7Y99A032EA 7313P 16C 155W 3.0G 1x 32GB 3200 940-8i 4G 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A031EA 7343 16C 190W 3.2G 1x 32GB 3200 940-8i 4G 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
7Y99A030EA 7453 28C 225W 2.8G 1x 32GB 3200 940-8i 4G 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
7Y99A02ZEA 7543P 32C 225W 2.8G 1x 32GB 3200 940-8i 4G 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
7Y99A02YEA 7713P 64C 225W 2.0G 1x 32GB 3200 940-8i 4G 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
Models with second-generation AMD EPYC processors
7Y99A020EA 7232P 8C 120W 3.1G 1x 32GB 2933 930-8i 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A021EA 7232P 8C 120W 3.1G 1x 32GB 2933 Onboard AHCI 4x 3.5" SAS Open bay Open 3x LP x16 / 1 1x 550W (Y) Yes 7x Std Slide
7Y99A00KEA 7262 8C 155W 3.2G 1x 32GB 3200 Onboard AHCI 10x 2.5" (6xSAS + 4xAny) Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A023EA 7282 16C 120W 2.4G 1x 32GB 2933 Option Optional 2.5" Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A00LEA 7302P 16C 155W 3.0G 1x 32GB 3200 Onboard AHCI 10x 2.5" (6xSAS + 4xAny) Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A00NEA 7302P 16C 155W 3.0G 1x 32GB 3200 Onboard AHCI 4x 3.5" SAS Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A022EA 7302P 16C 155W 3.0G 1x 32GB 3200 Option Optional 2.5" Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Std Slide
7Y99A01YEA 7402P 24C 180W 2.8G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
7Y99A00JEA 7502P 32C 180W 2.5G 1x 32GB 3200 Onboard AHCI 10x 2.5" (6xSAS + 4xAny) Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Perf Slide
7Y99A01ZEA 7552 48C 200W 2.2G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 3x LP x16 / 1 1x 750W HS (Y) Yes 7x Perf Slide
7Y99A00HEA 7702P 64C 200W 2.0G 1x 32GB 3200 Onboard AHCI 10x 2.5" (6xSAS + 4xAny) Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Perf Slide
7Y99A00MEA 7742 64C 225W 2.25G 1x 32GB 3200 Onboard AHCI 10x 2.5" (6xSAS + 4xAny) Open bay Open Open / 0 1x 1100W HS (Y) Yes 6x Perf Slide

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for Hong Kong, Taiwan, Korea (HTK)

Table 8. Models for Hong Kong, Taiwan, Korea (HTK)
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
TopSeller models with a 3-year model (machine type 7Y99)
7Y991002CN 7302P 16C 155W 3.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Std Fric
7Y99A00ZCN 7302P 16C 155W 3.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Std Fric
7Y99A010CN 7402P 24C 180W 2.8G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A033CN 7402P 24C 180W 2.8G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y991003CN 7502P 32C 180W 2.5G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A012CN 7502P 32C 180W 2.5G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y991004CN 7702P 64C 200W 2.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A013CN 7702P 64C 200W 2.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for India

Table 9. Models for India
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
TopSeller models with a 3-year model (machine type 7Y99)
7Y99A011SG 7302P 16C 155W 3.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Std Fric
7Y99A00SSG 7402P 24C 180W 2.8G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A00PSG 7502P 32C 180W 2.5G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric
7Y99A00TSG 7702P 64C 200W 2.0G 1x 32GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 2x 750W HS (Y) Yes 6x Perf Fric

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for Japan

Table 10. Models for Japan
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
TopSeller models with a 3-year model (machine type 7Y99)
7Y99A01BJP 7262 8C 155W 3.2G 1x 16GB 3200 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 1x 750W HS (N) Yes 6x Std Slide
7Y99A015JP 7302P 16C 155W 3.0G 1x 16GB 3200 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 1x 750W HS (N) Yes 6x Std Slide
7Y99A019JP 7502P 32C 180W 2.5G 1x 16GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 1x 750W HS (N) Yes 6x Perf Slide
7Y99A01DJP 7702P 64C 200W 2.0G 1x 16GB 3200 730-8i 2GB 8x 2.5" SAS Open bay 4x1Gb 5719 1x FH x16 / 0 1x 750W HS (N) Yes 6x Perf Slide

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for Latin American countries (except Brazil)

Table 11. Models with a 3-year warranty for Latin American countries (except Brazil)
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
Standard models with a 3-year model (machine type 7Y99)
Models with third-generation AMD EPYC processors
7Y99A01PLA 7313P 16C 155W 3.0G 1x 32GB 3200 730-8i 1GB 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A034LA 7313P 16C 155W 3.0G 1x 16GB 3200 540-8i 8x 2.5" SAS Open bay Open Open / 1 1x 750W HS (Y) Yes 7x Std Slide CMA
Models with second-generation AMD EPYC processors
7Y99A02ULA 7232P 8C 120W 3.1G 1x 16GB 2933 530-8i 4x 3.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 550W (Y) Yes 6x Std Slide
7Y991000LA 7262 8C 155W 3.2G 1x 16GB 3200 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01MLA 7262 8C 155W 3.2G 1x 16GB 2933 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A02TLA 7272 12C 120W 2.6G 1x 16GB 2933 530-8i 4x 3.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 550W (Y) Yes 6x Std Slide
7Y991001LA 7302P 16C 155W 3.0G 1x 32GB 3200 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01NLA 7302P 16C 155W 3.0G 1x 16GB 2933 530-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01QLA 7402P 24C 180W 2.8G 1x 32GB 2933 730-8i 1GB 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 1100W HS (Y) Yes 6x Perf Slide
7Y99A01RLA 7502P 32C 180W 2.5G 1x 32GB 2933 930-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 1100W HS (Y) Yes 6x Perf Slide
7Y99A01SLA 7702P 64C 200W 2.0G 1x 64GB 2933 930-8i 8x 2.5" SAS Open bay 4x1Gb 5719 3x LP x16 / 0 1x 1100W HS (Y) Yes 6x Perf Slide

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Models for USA and Canada

Table 12. Models for USA and Canada
Model AMD EPYC processor† Memory RAID Drive bays OCP Slots* Power
supplies
(cords)
Front
VGA
Fans Rail
kit
Standard models with a 3-year model (machine type 7Y99)
Models with 3rd-generation AMD EPYC processors
7Y99A039NA 7203P 8C 120W 2.8G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 1x FH x16 / 0 2x 1100W (Y) Yes 6x Std Slide
7Y991005NA 7203P 8C 120W 2.8G 2x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W (Y) Yes 6x Std Slide
7Y99A038NA 7303P 16C 130W 2.4G 1x 32GB 3200 930-8i 8x 2.5" SAS Open bay Open 1x FH x16 / 0 2x 1100W (Y) Yes 6x Std Slide
7Y991006NA 7303P 16C 130W 2.4G 2x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W (Y) Yes 6x Std Slide
Models with 2nd-generation AMD EPYC processors
7Y99A028NA 7282 16C 120W 2.4G 1x 16GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A01ANA 7302P 16C 155W 3.0G 1x 16GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A02WNA 7302P 16C 155W 3.0G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 750W HS (Y) Yes 6x Std Slide
7Y99A016NA 7402P 24C 180W 2.8G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W HS (Y) Yes 6x Perf Slide
7Y99A02VNA 7402P 24C 180W 2.8G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W (Y) Yes 6x Perf Slide
7Y99A017NA 7502P 32C 180W 2.5G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W HS (Y) Yes 6x Perf Slide
7Y99A018NA 7702P 64C 200W 2.0G 1x 32GB 3200 Option Optional 2.5" Open bay Open Open / 0 1x 1100W HS (Y) Yes 6x Perf Slide

† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)

Processors

The SR635 supports processors in the AMD EPYC family of processors. The server supports one processor.

Processor options

The table below lists the supported AMD processors.

All supported processors have the following characteristics:

  • Third and second-generation AMD EPYC processors (formerly codenamed "Milan" and "Rome" respectively)
  • 7 nm process technology
  • Eight DDR4 memory channels
  • 128 PCIe 4.0 I/O lanes

Part numbers: Processors do not include an option part number because there are no field upgrades supported.

Table 13. Processor options for the SR635
Feature code Description
Third-generation AMD EPYC processors
BY56 ThinkSystem AMD EPYC 7203 8C 120W 2.8GHz Processor
BY57 ThinkSystem AMD EPYC 7203P 8C 120W 2.8GHz Processor
BF7H ThinkSystem AMD EPYC 72F3 8C 180W 3.7GHz Processor
BY58 ThinkSystem AMD EPYC 7303 16C 130W 2.4GHz Processor
BY59 ThinkSystem AMD EPYC 7303P 16C 130W 2.4GHz Processor
BF76 ThinkSystem AMD EPYC 7313 16C 155W 3.0GHz Processor
BF7B ThinkSystem AMD EPYC 7313P 16C 155W 3.0GHz Processor
BF7E ThinkSystem AMD EPYC 7343 16C 190W 3.2GHz Processor
BF7D ThinkSystem AMD EPYC 73F3 16C 240W 3.5GHz Processor
BF78 ThinkSystem AMD EPYC 7413 24C 180W 2.65GHz Processor
BF72 ThinkSystem AMD EPYC 7443 24C 200W 2.85GHz Processor
BF79 ThinkSystem AMD EPYC 7443P 24C 200W 2.85GHz Processor
BF74 ThinkSystem AMD EPYC 7453 28C 225W 2.75GHz Processor
BF7G ThinkSystem AMD EPYC 74F3 24C 240W 3.2GHz Processor
BF7A ThinkSystem AMD EPYC 7513 32C 200W 2.6GHz Processor
BF77 ThinkSystem AMD EPYC 7543 32C 225W 2.8GHz Processor
BF71 ThinkSystem AMD EPYC 7543P 32C 225W 2.8GHz Processor
BF7F ThinkSystem AMD EPYC 75F3 32C 280W 2.95GHz Processor
BGQ5 ThinkSystem AMD EPYC 7643 48C 225W 2.3GHz Processor
BY5A ThinkSystem AMD EPYC 7643P 48C 225W 2.3GHz Processor
BF75 ThinkSystem AMD EPYC 7663 56C 240W 2.0GHz Processor
BY5B ThinkSystem AMD EPYC 7663P 56C 240W 2.0GHz Processor
BF7C ThinkSystem AMD EPYC 7713 64C 225W 2.0GHz Processor
BF70 ThinkSystem AMD EPYC 7713P 64C 225W 2.0GHz Processor
BF73 ThinkSystem AMD EPYC 7763 64C 280W 2.45GHz Processor
Second-generation AMD EPYC processors
B766 ThinkSystem AMD EPYC 7232P 8C 120W 3.1GHz Processor
B6VU ThinkSystem AMD EPYC 7252 8C 120W 3.1GHz Processor
B6TS ThinkSystem AMD EPYC 7262 8C 155W 3.2GHz Processor
BCE9 ThinkSystem AMD EPYC 7F32 8C 180W 3.7GHz Processor
B767 ThinkSystem AMD EPYC 7272 12C 120W 2.9GHz Processor
B6VZ ThinkSystem AMD EPYC 7282 16C 120W 2.8GHz Processor
B6TV ThinkSystem AMD EPYC 7302 16C 155W 3.0GHz Processor
B6VV ThinkSystem AMD EPYC 7302P 16C 155W 3.0GHz Processor
BCE8 ThinkSystem AMD EPYC 7F52 16C 240W 3.5GHz Processor
B6W0 ThinkSystem AMD EPYC 7352 24C 155W 2.3GHz Processor
B6VW ThinkSystem AMD EPYC 7402 24C 180W 2.8GHz Processor
B6TT ThinkSystem AMD EPYC 7402P 24C 180W 2.8GHz Processor
BCEA ThinkSystem AMD EPYC 7F72 24C 240W 3.2GHz Processor
B6TU ThinkSystem AMD EPYC 7452 32C 155W 2.35 GHz Processor
B5XG ThinkSystem AMD EPYC 7502 32C 180W 2.5GHz Processor
B6VX ThinkSystem AMD EPYC 7502P 32C 180W 2.5GHz Processor
BABP ThinkSystem AMD EPYC 7532 32C 200W 2.4GHz Processor
B6W2 ThinkSystem AMD EPYC 7542 32C 225W 2.9GHz Processor
B6W1 ThinkSystem AMD EPYC 7552 48C 200W 2.2GHz Processor
B6W3 ThinkSystem AMD EPYC 7642 48C 225W 2.3GHz Processor
BABN ThinkSystem AMD EPYC 7662 64C 225W 2.0GHz Processor
B6TR ThinkSystem AMD EPYC 7702 64C 200W 2.0GHz Processor
B6VY ThinkSystem AMD EPYC 7702P 64C 200W 2.0GHz Processor
B5XF ThinkSystem AMD EPYC 7742 64C 225W 2.25 GHz Processor
BAVP ThinkSystem AMD EPYC 7H12 64C 280W 2.6GHz Processor

Processor features

The following table lists the features of the supported processors.

P suffix: Processor models with a P suffix are designated as single-socket processors. They have identical features to the non-P equivalent processors.

The following table lists the features of the supported processors.

Table 14. Processor specifications
EPYC
model**
Cores /
Threads
Base
Frequency
Max Boost
Frequency†
L3 Cache Memory
channels
Memory
bus
TDP
Third-generation AMD EPYC processors
7203 / 7203P 8 / 16 2.8GHz 3.4 GHz 64 MB 8 3200 MHz 120W
72F3 8 / 16 3.7 GHz 4.1 GHz 256 MB 8 3200 MHz 180 W
7303 / 7303P 16 / 32 2.4GHz 3.4 GHz 64 MB 8 3200 MHz 130W
7313 / 7313P 16 / 32 3.0 GHz 3.7 GHz 128 MB 8 3200 MHz 155 W
7343 16 / 32 3.2 GHz 3.9 GHz 128 MB 8 3200 MHz 190 W
73F3 16/ 32 3.5 GHz 4.0 GHz 256 MB 8 3200 MHz 240 W
7413 24 / 48 2.65 GHz 3.6 GHz 128 MB 8 3200 MHz 180 W
7443 / 7443P 24 / 48 2.85 GHz 4.0 GHz 128 MB 8 3200 MHz 200 W
7453 28 / 56 2.75 GHz 3.45 GHz 64 MB 8 3200 MHz 225 W
74F3 24 / 48 3.2 GHz 4.0 GHz 256 MB 8 3200 MHz 240 W
7513 32 / 64 2.6 GHz 3.65 GHz 128 MB 8 3200 MHz 200 W
7543 / 7543P 32 / 64 2.8 GHz 3.7 GHz 256 MB 8 3200 MHz 225 W
75F3 32 / 64 2.95 GHz 4.0 GHz 256 MB 8 3200 MHz 280 W
7643 / 7643P 48 / 96 2.3 GHz 3.6 GHz 256 MB 8 3200 MHz 225 W
7663 / 7663P 56 / 112 2.0 GHz 3.5 GHz 256 MB 8 3200 MHz 225 W
7713 / 7713P 64 / 128 2.0 GHz 3.675 GHz 256 MB 8 3200 MHz 225 W
7763 64 / 128 2.45 GHz 3.5 GHz 256 MB 8 3200 MHz 280 W
Second-generation AMD EPYC processors
7232P 8 / 16 3.1 GHz 3.2 GHz 32 MB 8 3200 MHz* 120 W
7252 8 / 16 3.1 GHz 3.2 GHz 64 MB 8 3200 MHz* 120 W
7262 8 / 16 3.2 GHz 3.4 GHz 128 MB 8 3200 MHz 155W
7F32 8 / 16 3.7 GHz 3.9 GHz 128 MB 8 3200 MHz 180W
7272 12 / 24 2.9 GHz 3.2 GHz 64 MB 8 3200 MHz* 120 W
7282 16 / 32 2.8 GHz 3.2 GHz 64 MB 8 3200 MHz* 120 W
7302 / 7302P 16 / 32 3.0 GHz 3.3 GHz 128 MB 8 3200 MHz 155 W
7F52 16 / 32 3.5 GHz 3.9 GHz 256 MB 8 3200 MHz 240W
7352 24 / 48 2.3 GHz 3.2 GHz 128 MB 8 3200 MHz 155 W
7402 / 7402P 24 / 48 2.8 GHz 3.35 GHz 128 MB 8 3200 MHz 180 W
7F72 24 / 48 3.2 GHz 3.7 GHz 192 MB 8 3200 MHz 240W
7452 32 / 64 2.35 GHz 3.35 GHz 128 MB 8 3200 MHz 155 W
7502 / 7502P 32 / 64 2.5 GHz 3.35 GHz 128 MB 8 3200 MHz 180 W
7532 32 / 64 2.4 GHz 3.3 GHz 256 MB 8 3200 MHz 200W
7542 32 / 64 2.9 GHz 3.4 GHz 128 MB 8 3200 MHz 225 W
7552 48 / 96 2.2 GHz 3.3 GHz 192 MB 8 3200 MHz 200 W
7642 48 / 96 2.3 GHz 3.3 GHz 256 MB 8 3200 MHz 225 W
7662 64 / 128 2.0 GHz 3.3 GHz 256 MB 8 3200 MHz 225W
7702 / 7702P 64 / 128 2.0 GHz 3.35 GHz 256 MB 8 3200 MHz 200 W
7742 64 / 128 2.25 GHz 3.4 GHz 256 MB 8 3200 MHz 225 W
7H12 64 / 128 2.6 GHz 3.3 GHz 256 MB 8 3200 MHz 280W

† The maximum single-core frequency at with the processor is capable of operating
* This processor supports 8 memory channels at 3200 MHz, however performance is optimized for 4 channels at 2666 MHz
** Processors with a P suffix are single-socket capable processors

UEFI operating modes

The SR635 offers preset operating modes that affect energy consumption and performance. These modes are a collection of predefined low-level UEFI settings that simplify the task of tuning the server to suit your business and workload requirements.

The following table lists the feature codes that allow you to specify the mode you wish to preset in the factory for CTO orders.

Table 15. UEFI operating mode presets in DCSC
Feature code Description
BFYA Operating mode selection for: "Maximum Efficiency Mode"
BFYB Operating mode selection for: "Maximum Performance Mode"

The preset modes for the SR635 are as follows:

  • Maximum Efficiency Mode (feature BFYA): Maximizes performance/watt efficiency while maintaining reasonable performance
  • Maximum Performance Mode (feature BFYB): Achieves maximum performance but with higher power consumption and lower energy efficiency.

For details about these preset modes, and all other performance and power efficiency UEFI settings offered in the SR635, see the paper "Tuning UEFI Settings for Performance and Energy Efficiency on AMD Processor-Based ThinkSystem Servers", available from https://lenovopress.lenovo.com/lp1267.

Memory options

The SR635 uses Lenovo TruDDR4 memory operating at up to 3200 MHz. The processors have 8 memory channels and support 2 DIMMs per channel, for a total of 16 DIMMs. The server supports up to 2TB of memory using 16x 128 GB 3DS RDIMMs.

The server supports these memory DIMMs:

  • 2933 MHz DIMMs, that operate at 2933 MHz both at 1 DIMM per channel and 2 DIMMs per channel
  • 3200 MHz DIMMs, that operate at 3200 MHz at 1 DIMM per channel, and at 2933 MHz at 2 DIMMs per channel

The following table lists the memory options that are available for the server.

Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

Table 16. Supported memory options
Part
number
Feature
code
Description Maximum
supported
2933 MHz memory
4ZC7A08739 B7MS ThinkSystem 8GB TruDDR4 2933MHz (1Rx8 1.2V) RDIMM-A 16
4ZC7A08740 B7MT ThinkSystem 16GB TruDDR4 2933MHz (1Rx4 1.2V) RDIMM-A 16
4ZC7A08741 B7MU ThinkSystem 16GB TruDDR4 2933MHz (2Rx8 1.2V) RDIMM-A 16
4ZC7A08742 B7MV ThinkSystem 32GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM-A 16
4ZC7A08744 B7MW ThinkSystem 64GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM-A 16
4ZC7A15113 B587 ThinkSystem 128GB TruDDR4 2933MHz (4Rx4 1.2V) 3DS RDIMM 16*
3200 MHz memory
4ZC7A15121 B5XD ThinkSystem 16GB TruDDR4 3200MHz (2Rx8 1.2V) RDIMM-A 16
4ZC7A15122 B5XE ThinkSystem 32GB TruDDR4 3200MHz (2Rx4 1.2V) RDIMM-A 16
4ZC7A15123 B8NU ThinkSystem 32GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM-A 16
4ZC7A15124 B5XC ThinkSystem 64GB TruDDR4 3200MHz (2Rx4 1.2V) RDIMM-A 16
4ZC7A15125 B8NT ThinkSystem 128GB TruDDR4 3200MHz (4Rx4, 1.2V) 3DS RDIMM-A 16

* Supported in the SR635 only with an EPYC 7002 processor. Not supported with an EPYC 7003 processor.

The following rules apply when selecting the memory configuration:

  • The 128GB 2933 MHz 3DS RDIMM, 4ZC7A15113, is only supported in the SR635 with an EPYC 7002 processor.
  • The server supports RDIMMs and 3DS RDIMMs
  • Mixing of RDIMMs and 3DS RDIMMs is not supported
  • Mixing x4 and x8 DIMMs is supported, but not in the same channel
  • Mixing of DIMM rank counts is supported. Follow the required installation order installing the DIMMs with the higher rank counts first.
  • Mixing of DIMM capacities is supported, however only two different capacities are supported across all channels of the processor (eg 32GB and 64GB). Follow the required installation order installing the larger DIMMs first.
  • Mixing of 3200 MHz and 2933 MHz DIMMs is supported. Installed memory will operate at the lower speed.
  • Memory mirroring and memory rank sparing are not supported.
  • When a GPU is added as a field upgrade, all empty DIMM slots must have a dummy DIMM blank installed in each DIMM slot, to ensure the optimal air flow. Ordering information is in the following table. For CTO orders, the dummy DIMMs are derived by the configurator.
Table 17. ThinkSystem Dummy DIMM Kit
Part number Description Quantity required
4M27A11810 ThinkSystem Dummy DIMM Package Kit
(contains 24 dummy memory DIMMs)
1

For best performance, consider the following:

  • Ensure the memory installed is at least the same speed as the memory bus of the selected processor.
  • Populate memory DIMMs in quantities of 8 or 16, so that all memory channels are used.
  • Populate memory channels so they all have the same total memory capacity.
  • For more details on how to best configure the memory subsystem for performance, refer to the Lenovo Press paper “Balanced Memory Configurations with 2nd Gen and 3rd Gen AMD EPYC Processors” available from
    https://lenovopress.com/lp1268-balanced-memory-configurations-with-amd-epyc-processors

The following memory protection technologies are supported:

  • ECC detection/correction
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • Patrol/Demand Scrubbing
  • DRAM Address Command Parity with Replay
  • DRAM Uncorrected ECC Error Retry
  • Post Package Repair

Internal storage

The SR635 supports 4x 3.5-inch or 16x 2.5-inch drive bays or a combination of drive bays, depending on the selected chassis and backplane configuration. The server also supports configurations without any drive bays if desired.

All drives are hot-swap and are accessible from the front, from the rear, or from drive bays that are located in the middle of the server (accessible when you remove the top cover of the server).

The three drive bay zones are as follows:

  • Front: 4x 3.5-inch hot-swap bays or up to 10x 2.5-inch hot-swap bays
  • Mid (internal): 4x 2.5-inch hot-swap bays
  • Rear: up to 2x 2.5-inch hot-swap bays

The server also supports one or two M.2 drives, installed in an M.2 adapter.

In this section:

NVMe drive support

PM983 hot-swap support: To support hot-swap of PM983 NVMe drives, the server needs to have UEFI v2.0 (Build ID CFE108O) or later installed.

The SR635 supports NVMe drives to maximize storage performance. The server supports up to 16 NVMe drives without oversubscription (that is, each x4 drive has a full x4 connection (4 lanes) to the processor):

  • 10x NVMe drives in the front bays
  • 4x NVMe drives in the mid bays
  • 2x NVMe drives in the rear bays

The specifics of these configurations plus other NVMe-rich configurations are covered in the Supported drive bay combinations and  Adapters selections sections.

The 10x NVMe drives at the front makes use of the 10-bay AnyBay backplane (feature B5VS) which requires SAS/SATA cabling and controllers as well as the NVMe cabling. However, if 16x NVMe drive bays are configured (ie all drive bays in the server populated with NVMe drives), then the server can be configured in the DCSC configurator without SAS/SATA cabling and controllers. Note that all 16x NVMe drive bays must be configured (using backplanes B5VS, B5VN and B5VQ); configurations of 10 or 12 or 14x NVMe drive bays will require SAS/SATA cabling and controllers.

15mm NVMe drives: 15mm NVMe SSDs are not supported in the mid or rear drive bays due to thermal requirements. Only 7mm NVMe drives are supported in those zones.

Front drive bays

The front drive bay zone supports the following configurations:

  • 3.5-inch drive bays
    • No backplane and no drives (supports field upgrades)
    • 4x 3.5-inch SAS/SATA
  • 2.5-inch drive bays
    • No backplane and no drives (supports field upgrades)
    • 8x 2.5-inch hot-swap SAS/SATA
    • 6x 2.5-inch hot-swap SAS/SATA + 4x 2.5-inch hot-swap AnyBay
    • 10x 2.5-inch hot-swap AnyBay

These configurations are shown in the following figure.

SR635 front drive bay configurations
Figure 6. SR635 front drive bay configurations

The backplanes used to provide these drive bays are listed in the following table.

10x NVMe drive support: The server supports 10x 2.5-inch NVMe-only drive bays in the front of the server. Such support makes use of the 10-bay AnyBay backplane (feature B5VS), however the SAS/SATA connectors on the backplane are not connected, and no SAS/SATA cabling or controllers are configured.

Table 18. Backplanes for front drive bays
Part
number
Feature
code
Description Maximum
supported
Front 3.5-inch drive backplanes
See note* AUW8 ThinkSystem 1U 3.5" SATA/SAS 4-Bay Backplane
(4x 3.5-inch SAS/SATA backplane)
1
Front 2.5-inch drive backplanes
See note* B7K3 ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane
(8x 2.5-inch SAS/SATA backplane)
1
See note* AUW9 ThinkSystem 1U 10x2.5" (6x SAS/SATA 4x AnyBay) Backplane
(10-bay 2.5-inch backplane with 6x SAS/SATA + 4x AnyBay bays†)
1
See note* B5VS ThinkSystem 1U 10x2.5" PCIe Gen4 AnyBay Backplane
(10-bay 2.5-inch backplane with 10x AnyBay bays†)
1

* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.
† AnyBay bays support SAS or SATA or NVMe drives; can also be configured as 10x NVMe drives without SAS/SATA cabling.

Mid drive bays

The SR635 optionally supports 4x 2.5-inch hot-swap NVMe drive bays installed in the middle of the server chassis. The drive bays are accessible by removing the top lid of the server and levering the mid drive chassis into an angled open position.

The drive bays, angled up, are shown in the following figure.

Mid-chassis drive bays
Figure 7. Mid-chassis drive bays (open position)

The backplanes used to provide these drive bays are listed in the following table.

Table 19. Backplanes for mid drive bays
Part
number
Feature
code
Description Maximum
supported
Mid - 2.5-inch drive backplanes
See note* B5VN ThinkSystem 2.5” NVMe 4-Bay Middle Backplane
(4x 2.5-inch NVMe backplane)
1

* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.

The use of drive bays in the mid-chassis area has the following configuration rules:

  • Only NVMe drives are supported in the mid chassis area. SAS and SATA drives are not supported.
  • The mid drive cage is only supported in conjunction with the 10x 2.5-inch AnyBay backplane (feature AUW9) or the 4x 3.5-inch SAS/SATA backplane (feature AUW8) for the front drives. The use of other front-drive backplanes with the mid cage is not supported.
  • The mid drive cage occupies the same physical space as the M.2 module, internal PCIe slot (slot 4) and two of the three holders for RAID power module (supercaps). As a result, the M.2 module, slot 4 and two supercaps cannot be installed.

Rear drive bays

The SR635 supports hot-swap drives installed at the rear of the server chassis. Supported configurations are as follows:

  • 2x 2.5-inch hot-swap SAS/SATA drive bays
  • 2x 2.5-inch hot-swap NVMe drive bays

The configurations are shown in the following figure.

SR635 rear drive bay configurations
Figure 8. Rear drive bay configurations

The backplanes used to provide these drive bays are listed in the following table.

Table 20. Backplanes for rear drive bays
Part
number
Feature
code
Description Maximum
supported
Rear - 2.5-inch drive backplanes
See note* B5VR ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Backplane
(2x 2.5-inch SAS/SATA backplane)
1
See note* B5VQ ThinkSystem 1U 2x2.5" NVMe Rear Backplane
(2x 2.5-inch NVMe backplane)
1

* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.

The use of rear drive bays has the following configuration rules:

  • Slots 2 and 3 are not available
  • Slot 1 is a low-profile slot
  • GPUs are not supported

Supported drive bay combinations

This section describes the various combinations of 3.5-inch and 2.5-inch drives that the server supports. The drive bay combinations are grouped based on the drive type at the front of the server, 3.5-inch or 2.5-inch.

3.5-inch drive bay chassis

The following table shows the supported combinations when the server is configured with a 3.5-inch chassis (where the front drive bays are 3.5-inch). The choice of storage controller for each configuration is listed in the Adapter selections section.

Table 21. Drive bay combinations with 3.5-inch chassis (Blue cells = SAS/SATA, Red cells = NVMe)
Config Total
drives
Front bays (3.5") Mid bays (2.5") Rear bays (2.5")
SAS/SATA NVMe SAS/SATA NVMe
A 4 4 0 0 0
B 6 4 0 2 0
C 6 4 0 0 2
D 8 4 4 0 0

2.5-inch drive bay chassis

The following table shows the supported combinations when the server is configured with a 2.5-inch chassis (where the front drive bays are 2.5-inch). The choice of storage controller for each configuration is listed in the Adapter selections section.

Table 22. Drive bay combinations with 2.5-inch chassis (Blue cells = SAS/SATA, Red cells = NVMe, Purple cells = AnyBay)
Config Total
drives
Front bays (2.5") Mid bays (2.5") Rear bays (2.5")
SAS/SATA AnyBay NVMe NVMe SAS/SATA NVMe
2.5-inch chassis - only SAS/SATA drives in the front bays
A 8 8 0 0 0 0 0
B 10 8 0 0 0 2 0
C 10 8 0 0 0 0 2
2.5-inch chassis - mix of SAS/SATA-only bays and AnyBay bays in the front
D 10 6 4 0 0 0 0
E 12 6 4 0 0 2 0
F 12 6 4 0 0 0 2
2.5-inch chassis - all AnyBay bays in the front
G 10 0 10 0 0 0 0
H 12 0 10 0 0 2 0
I 12 0 10 0 0 0 2
J 14 0 10 0 4 0 0
K 16 0 10 0 4 2 0
L 16 0 10 0 4 0 2
M 16 0 0 10 4 0 2

Adapter selections

The following tables lists the supported drive bay combinations plus the list of supported controller combinations supported by each of those drive bay combinations. Information about the controllers can be found in the Controllers for internal storage section.

Table 23. Drive bay combinations with 3.5-inch chassis (Blue cells = SAS/SATA, Red cells = NVMe)
Cfg Total
drives
Front bays
(3.5")
Mid bays
(2.5")
Rear bays (2.5") Supported controller combinations
(choose one)
(OB = Onboard)
SAS/SATA NVMe SAS/SATA NVMe
A 4 4 0 0 0
  • OB SATA
  • 530-8i
  • 730-8i 1G
  • 730-8i 2G
  • 930-8i
  • 430-8i
B 6 4 0 2 0
  • OB SATA
  • 530-8i
  • 730-8i 1G
  • 730-8i 2G
  • 930-8i
  • 430-8i
C 6 4 0 0 2
  • OB SATA + OB NVMe
  • 530-8i + OB NVMe
  • 730-8i 1G + OB NVMe
  • 730-8i 2G + OB NVMe
  • 930-8i + OB NVMe
  • 430-8i + OB NVMe
D 8 4 4 0 0
  • OB SATA + OB NVMe (no M.2*)
  • 530-8i + OB NVMe (no M.2*)
  • 730-8i 1G + OB NVMe (no M.2*)
  • 430-8i + OB NVMe (no M.2*)

* The configurations with 4 mid drives do not support the M.2 Module because the mid drive bays and the M.2 Module occupy the same physical space.

Table 24. Drive bay combinations with 2.5-inch chassis (Blue cells = SAS/SATA, Red cells = NVMe, Purple cells = AnyBay)
Cfg Total
drives
Front bays (2.5") Mid bays
(2.5")
Rear bays (2.5") Supported controller combinations
(choose one)
(OB = Onboard)
SAS/ SATA AnyBay NVMe NVMe SAS/ SATA NVMe
2.5-inch chassis - only SAS/SATA drives in the front bays
A 8 8 0 0 0 0 0
  • OB SATA
  • 530-8i
  • 730-8i 1G
  • 730-8i 2G
  • 930-8i
  • 430-8i
B 10 8 0 0 0 2 0
  • OB SATA
  • 2x 530-8i
  • 2x 730-8i 1G
  • 1x 530-8i + 1x 430-8i
  • 1x 930-16i
  • 2x 430-8i
C 10 8 0 0 0 0 2
  • OB SATA + OB NVMe
  • 530-8i + OB NVMe
  • 730-8i 1G + OB NVMe
  • 730-8i 2G + OB NVMe
  • 930-8i + OB NVMe
  • 430-8i + OB NVMe
2.5-inch chassis - mix of SAS/SATA-only bays and AnyBay bays in the front
D 10 6 4 0 0 0 0
  • OB SATA + OB NVMe
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
E 12 6 4 0 0 2 0
  • OB SATA + OB NVMe (no M.2*)
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
F 12 6 4 0 0 0 2
  • OB SATA + OB NVMe
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
2.5-inch chassis - all AnyBay bays in the front
G 10 0 10 0 0 0 0
  • OB SATA + OB NVMe
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
H 12 0 10 0 0 2 0
  • OB SATA + OB NVMe (no M.2*)
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
I 12 0 10 0 0 0 2
  • 1x 930-16i + OB NVMe
  • 1x 430-16i + OB NVMe
J 14 0 10 0 4 0 0
  • 1x 930-16i+OB NVMe (no M.2*)
  • 1x 430-16i+OB NVMe (no M.2*)
K 16 0 10 0 4 2 0
  • 1x 930-16i+OB NVMe (no M.2*)
  • 1x 430-16i+OB NVMe (no M.2*)
L 16 0 10 0 4 0 2
  • 1x 930-16i+OB NVMe (no M.2*)
  • 1x 430-16i+OB NVMe (no M.2*)
M 16 0 0 10 4 0 2
  • OB NVMe (no M.2*)

* These configurations, with 12 total SATA drives connected to the onboard SATA controller, or 4 mid drive bays, do not support the use of the M.2 Module. The M.2 Module and the onboard SATA bays use the same ports on the system board and the mid drive bays occupy the same space as the M.2 Module.

Field upgrades

This section describes the available upgrades to the storage subsystem.

Backplane upgrades

The following table lists the option part numbers for the backplane kits that allow you to add additional drive bays as field upgrades. The table also lists what major components are included in each kit.

When adding drive bays, you will also need to add the appropriate storage controller(s). Consult the tables in the Adapter selections section to determine what controller sections are supported and what additional controllers you will need. Controllers are described in the Controllers for internal storage section.

Use with X40 adapters: These backplane kits in the table below include SAS/SATA cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you are adding or upgrading to RAID 940 adapters or 440 HBAs (collectively called X40 adapters), you will need to also order an X40 cable kit. See the Cable kits for 440 HBAs and RAID 940 adapters section for details.

Table 25. Drive backplane field upgrades
Part
number
Description Maximum
supported
Front - 3.5-inch drive backplane (see Front drive bays)
4XH7A09825

ThinkSystem SR635 3.5" SATA/SAS 4-Bay Backplane Kit

  • 1x 4-bay SAS/SATA backplane
  • SATA Cable Kits (power and SATA cables)
  • SAS/SATA Cable Kit (power cable, miniSAS-HD cable)
1
Front - 2.5-inch drive backplanes (see Front drive bays)
4XH7A09826

ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane Kit

  • 1x 8-bay SAS/SATA backplane
  • 2-bay filler
  • SATA Cable Kits (power and SATA cables)
  • SAS/SATA Cable Kits (power cables, miniSAS-HD cables)
1
4XH7A09827

ThinkSystem SR635 2.5" 4 Gen3 AnyBay 10-Bay BP Kit
(10-bay 2.5-inch backplane with 6x SAS/SATA bays + 4x AnyBay bays†)

  • 1x 10-bay backplane (4 bays are AnyBay)
  • SATA Cable Kits (power and SATA cables)
  • SAS/SATA Cable Kits (power cables, miniSAS-HD cables)
  • NVMe cables (two slimline 1x8-to-2x4 cables)
1
4XH7A09828

ThinkSystem SR635 2.5" 10 Gen4 AnyBay BP Kit
(10-bay 2.5-inch backplane where all bays are AnyBay bays†)

  • 1x 10-bay backplane (all bays are AnyBay)
  • SATA Cable Kits (power and SATA cables)
  • SAS/SATA Cable Kits (power cables, miniSAS-HD cables)
  • NVMe cable kit
1
Mid - 2.5-inch drive backplane (see Mid drive bays)
4XH7A09856

ThinkSystem SR635 2.5" NVMe Gen4 4-Bay Middle Drive Kit

  • Mid-chassis 2.5-inch drive cage
  • 4-bay 2.5-inch NVMe backplane
  • 7x Performance fans (replaces existing fans)
  • Air baffle (replace existing baffle)
  • NVMe Cable Kit (power cable, signal cable)
1
Rear - 2.5-inch drive backplanes (see Rear drive bays)
4XH7A09852

ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Drive Kit

  • Rear 2.5-inch drive cage
  • 2-bay 2.5-inch SAS/SATA rear backplane
  • 7x Performance fans (replaces existing fans)
  • SATA Cable Kit (power cable, SATA cable)
  • SAS/SATA Cable Kit (power cable, miniSAS-HD cable)
1
4XH7A80466

ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit v2

  • Rear 2.5-inch drive cage
  • 2-bay 2.5-inch NVMe rear backplane
  • 7x Performance fans (replaces existing fans)
  • NVMe Cable Kit (power cable, signal cable)
1
4XH7A09853

ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit

  • Rear 2.5-inch drive cage
  • 2-bay 2.5-inch NVMe rear backplane
  • 7x Performance fans (replaces existing fans)
  • NVMe Cable Kit (power cable, signal cable)
1

† AnyBay bays support SAS or SATA or NVMe drives

Cable kits for 440 HBAs and RAID 940 adapters

The backplane kits listed in the preceding table include cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you wish to use the backplane kits with RAID 940 adapters or 440 HBAs (collectively called X40 adapters), then you will also need to order an additional X40 cable kit to use instead of the cables in the backplane kit.

Unused cables: When adding an X40 adapter, you will order both the backplane kit and the relevant X40 cable kit, however the SAS/SATA data cable(s) in the backplane kit will not be used.

Upgrades from onboard SATA: If you are upgrading a system that currently uses the onboard SATA controller and has all necessary backplanes, simply order the relevant X40 cable kit as listed in the table.

Table 26. Cable kits for 440 HBAs and RAID 940 adapters
Backplane kits with X30 cables X40 cable kits also needed
Front - 3.5-inch drive backplane (see Front drive bays)
4XH7A09825 ThinkSystem SR635 3.5" SATA/SAS 4-Bay Backplane Kit 4XH7A61120 ThinkSystem SR635 3.5" SAS/SATA 4-Bay X40 RAID Cable Kit
Front - 2.5-inch drive backplanes (see Front drive bays)
4XH7A09826 ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane Kit 4XH7A61121 ThinkSystem SR635 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
4XH7A09827 ThinkSystem SR635 2.5" 4 Gen3 AnyBay 10-Bay BP Kit 4XH7A61136 ThinkSystem SR635 Front 6x2.5" SAS/SATA + 4x2.5" AnyBay X40 RAID Cable Kit
4XH7A09828 ThinkSystem SR635 2.5" 10 Gen4 AnyBay BP Kit 4XH7A61127 ThinkSystem SR635 2.5" SAS/SATA/AnyBay 10-Bay X40 RAID Cable Kit
Mid - 2.5-inch drive backplane (see Mid drive bays)
4XH7A09856 ThinkSystem SR635 2.5" NVMe Gen4 4-Bay Middle Drive Kit None Not supported – NVMe only
Rear - 2.5-inch drive backplanes (see Rear drive bays)
4XH7A09852 ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Drive Kit 4XH7A61128 ThinkSystem SR635 2.5" SAS/SATA 2-Bay Rear Backplane X40 RAID Cable Kit
4XH7A80466 ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit v2 None Not supported – NVMe only
4XH7A09853 ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit None Not supported – NVMe only

Cable kit for Onboard SATA controller upgrades (X30 adapters only)

If your existing server is configured with drive backplanes that are connected to onboard SATA ports and you wish to upgrade to an X30 RAID adapter or SAS HBA (RAID 930, 730, 530 adapters and 430 HBAs), you will need to order the cable kit listed in the following table along with the adapter(s). The cable kit includes the additional cables you will need to connect the existing backplane to the new X30 adapter. Note that the kit includes the cables needed for all supported combinations of backplanes; this means that some of the cables in the kit will not be used.

For X40 RAID adapters and HBAs, instead order one of the X40 cable kits listed in the Cable kits for 440 HBAs and RAID 940 adapters section.

Table 27. RAID adapter cable kit for servers with backplanes (X30 adapters only)
Part number Feature code Description
4X97A59749 BCCC

ThinkSystem SR635 SAS Cable Kit, contains five cables:

  • 800mm MiniSAS-HD to MiniSAS-HD Cable C, SC17A50746
  • 800mm Slimline4X to MiniSAS-HD Cable C, SC17A50732
  • Front BP SAS/SATA Combo Cable A, SC17A59349
  • 250mm HBA HD to HD Cable D, SC17A50750
  • Front 1U 10 AnyBay BP SAS/SATA Combo Cable, SC17A59347

The cables in the kit are used with existing backplanes as listed in the following table.

Table 28. Use of SR635 SAS Cable Kit
Existing backplane Needed cables
Front 3.5-inch 4x SATA/SATA Backplane 800mm MiniSAS-HD to MiniSAS-HD Cable C, SC17A50746
Front 2.5-inch 8x SAS/SATA Backplane Front BP SAS/SATA Combo Cable A, SC17A59349
Front 2.5-inch 4x AnyBay+6x SAS/SATA Backplane 800mm MiniSAS-HD to MiniSAS-HD Cable C, SC17A50746
Front 2.5-inch 10x AnyBay Backplane Front 1U 10 AnyBay BP SAS/SATA Combo Cable, SC17A59347
800mm Slimline4X to MiniSAS-HD Cable C, SC17A50732
Rear 2.5-inch 2x SAS/SATA Backplane 250mm HBA HD to HD Cable D, SC17A50750

RAID flash power module (supercap)

If you plan to add one of the RAID adapters that includes a RAID flash power module (supercap) as a field upgrade, then you will also need to order a Supercap installation kit for the power module. For CTO orders, the components in the installation kit are automatically derived when you select the RAID adapter. The adapters that this applies to are as follows:

  • ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter

There are three possible locations for supercaps, as shown in the following figure.

Location of all three supercaps
Figure 9. Location of all three supercaps in the SR635

The following configuration rules apply to the use of supercaps:

  • Locations 1 and 2 are not available if the mid-chassis drive cage is installed
  • Location 3 is only available with 2.5-inch front drive bays. It is not available if 3.5-inch front drives are used

When adding a RAID adapter and supercap as a field upgrade, order the supercap installation kit list listed in the following table.

Table 29. RAID Flash Power Module installation kit
Part number Feature code Description
4XH7A09847 B72A

ThinkSystem SR635/SR655 Supercap Installation Kit

  • 1x Bracket to hold two supercaps in their holders
  • 3x Supercap holders

The following figure shows the use of the components of the option kit to install 1 or 2 supercaps. The third supercap is installed in location 3 in front of the cooling fans and behind the front operator panel as shown in the preceding figure (2.5-inch chassis only; not available with 3.5-inch front drives).

Supercap Installation Kit
Figure 10. Supercap Installation Kit (locations 1 and 2)

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution or as additional storage. The M.2 drives install into an M.2 module which is mounted horizontally in the server adjacent to the internal storage controller slot as shown in the Components and connectors section.

M.2 restriction: The M.2 Module cannot be used in certain drive bay combinations:

  • When 12 SATA or AnyBay drive bays are configured (10 front, 2 rear) and the SATA drives are connected to the onboard SATA controller (onboard SATA and M.2 use the same connector)
  • When 4 mid-chassis drive bays are configured (M.2 occupies the same space)

See Adapter selections for the specific combinations where the M.2 Module is not supported.

There are two M.2 modules supported, as listed in the following table. The table also includes the cable kit needed for field upgrades.

Field upgrades: When ordering either option part number as a field upgrade, you will also need to order the M.2 Cable Kit which includes the necessary cables to connect the M.2 modules to the server. For CTO orders, the cable kit is not required; the cable and brackets are automatically included in the order.

Table 30. M.2 modules
Part
number
Feature
code
Description Maximum
supported
4Y37A09739 B5XH ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit 1
4Y37A09738 B5XJ ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit 1
4X97A59730 None

ThinkSystem SR635/SR655 M.2 Cable Kit
(only needed for field upgrade to add 4Y37A09739 or 4Y37A09738)

  • Bracket to mount the M.2 module
  • Bracket for two supercap modules
  • M.2 signal/power cable
1

Supported drives are listed in the Internal drive options section.

The SATA RAID Enablement Kit has the following features:

  • Supports one or two SATA M.2 drives
  • Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
  • RAID support via an onboard Marvell 88SE9230 SATA RAID Controller
  • Support JBOD, RAID-0 and RAID-1 (RAID support requires two M.2 drives)
  • PCIe 2.0 x2 host interface; 6Gbps SATA connection to the drives
  • Management and configuration support via UEFI and OS-based tools
  • Supports monitoring and reporting of events and temperature through I2C
  • Firmware update via Lenovo firmware update tools

The SATA/NVMe Enablement Kit has the following features:

  • Supports one or two M.2 drives, either SATA or NVMe
  • When two drives installed, they must be either both SATA or both NVMe
  • Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
  • JBOD support only; no RAID support
  • Either 6Gbps SATA or PCIe 3.0 x1 interface to the drives depending on the drives installed
  • Supports monitoring and reporting of events and temperature through I2C
  • Firmware update via Lenovo firmware update tools

For further details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

Controllers for internal storage

The SR635 offers a variety of controller options for internal drives:

  • Onboard SATA ports for up to 12 SATA drives
  • RAID adapters and HBAs for SAS/SATA drives
  • Onboard NVMe ports (for up to 16 NVMe drives)

The following table lists the adapters used for the internal storage of the server.

Table 31. Internal Storage adapter support
Part
number
Feature
code
Description Power module
(supercap)
Slots
supported
Maximum
supported
SAS/SATA RAID - PCIe 3.0
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter No 4, 1, 3, 2 2
4Y37A78834 BMFT ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter No 4, 1, 3, 2 2
7Y37A01083* AUNH* ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter No 4, 1, 3, 2 2
4Y37A09722 B4RQ ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter Included 4, 1, 3, 2 1
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter Included 4, 1, 3, 2 1
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter Included 4, 1, 3, 2 1
SAS/SATA RAID - PCIe 4.0 (No support for Tri-Mode)
4Y37A09728 B8NY ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter Included 4, 1, 3, 2 1
4Y37A78600 BM35 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter Included 4, 1, 3, 2 1
SAS/SATA HBA - PCIe 3.0
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA No 1, 3, 2 2
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA No 1, 3, 2 1
SAS/SATA HBA - PCIe 4.0
4Y37A78601 BM51 ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA No 4, 1, 3, 2 2
4Y37A78602 BM50 ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA No 4, 1, 3, 2 1

* The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.

For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference#sr635-support=SR635

For more information about the adapters see the product guides in the RAID adapters or HBA sections of the Lenovo Press web site:
https://lenovopress.com/servers/options/raid
https://lenovopress.com/servers/options/hba

Configuration notes:

  • Tri-Mode not supported: In the SR635, the Tri-Mode (Trimode) feature of the RAID 940-8i and 940-16i adapters (support for NVMe U.3 drives) is not supported.
  • Field upgrades: If you are adding a RAID adapter to the SR635 as a field upgrade, you will need a Supercap Installation Kit as described in the Field upgrades section. For use of 940 RAID adapters or 440 HBAs, you will also need a cable kit. Take note of the configuration rules in that section.
  • RAID 530-8i firmware: If you plan to use the RAID 530-8i in the SR655, it must have firmware 50.3.0-1032 or later applied before it can be used in the server. If the adapter you plan to use has older firmware (for example, you are using an adapter you previously purchased), it must first be upgrade by installing it in another server and upgrading the firmware there. For more information, see Support tip HT509177.

Internal drive options

The following tables list the drive options for internal storage of the server.

M.2 drives:

M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

SED support: The tables include a column to indicate which drives support SED encryption. The encryption functionality can be disabled if needed. Note: Not all SED-enabled drives have "SED" in the description.

Table 32. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 12
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD No 12
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 12
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 12
Table 33. 2.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 12
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD No 12
Table 34. 2.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80340 BNW8 ThinkSystem 2.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80341 BNW9 ThinkSystem 2.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80342 BNW6 ThinkSystem 2.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80343 BP3K ThinkSystem 2.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 12
2.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80318 BNWC ThinkSystem 2.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80319 BNWE ThinkSystem 2.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80320 BNWF ThinkSystem 2.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80321 BP3E ThinkSystem 2.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80322 BP3J ThinkSystem 2.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80323 BP3D ThinkSystem 2.5" PM1653 30.72TB Read Intensive SAS 24Gb HS SSD Support 12
Table 35. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A83214 BR10 ThinkSystem 2.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83215 BR0Z ThinkSystem 2.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83216 BR0Y ThinkSystem 2.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83217 BR0X ThinkSystem 2.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A70006 BG07 ThinkSystem 2.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70005 BG06 ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70007 BFZZ ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD SED Support 12
4XB7A70004 BG05 ThinkSystem 2.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70003 BG04 ThinkSystem 2.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10219 B4Y4 ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10230 B4Y5 ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10231 B4Y6 ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10232 B4Y7 ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 12
2.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17062 B8HU ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A17063 B8J4 ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A17065 B8JA ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 12
2.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A38175 B91A ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A38176 B91B ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17054 B91C ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17055 B91D ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 12
Table 36. 2.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A90884 BYM2 ThinkSystem 2.5" Multi Vendor 480GB Mixed Use SATA 6Gb HS SSD v2 No 12
4XB7A90885 BYM4 ThinkSystem 2.5" Multi Vendor 960GB Mixed Use SATA 6Gb HS SSD v2 No 12
4XB7A90886 BYM5 ThinkSystem 2.5" Multi Vendor 1.92TB Mixed Use SATA 6Gb HS SSD v2 No 12
4XB7A90887 BYM6 ThinkSystem 2.5" Multi Vendor 3.84TB Mixed Use SATA 6Gb HS SSD v2 No 12
4XB7A82289 BQ21 ThinkSystem 2.5" 5400 MAX 480GB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82290 BQ24 ThinkSystem 2.5" 5400 MAX 960GB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82291 BQ22 ThinkSystem 2.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82292 BQ23 ThinkSystem 2.5" 5400 MAX 3.84TB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A17125 BA7Q ThinkSystem 2.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17126 BA4T ThinkSystem 2.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17127 BA4U ThinkSystem 2.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17128 BK7L ThinkSystem 2.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17091 B8J7 ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A64222 BEMB ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A13633 B49L ThinkSystem 2.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13634 B49M ThinkSystem 2.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13635 B49N ThinkSystem 2.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13636 B49P ThinkSystem 2.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
2.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A90872 BYLQ ThinkSystem 2.5" Multi Vendor 240GB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A90873 BYLR ThinkSystem 2.5" Multi Vendor 480GB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A90874 BYLS ThinkSystem 2.5" Multi Vendor 960GB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A90875 BYLT ThinkSystem 2.5" Multi Vendor 1.92TB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A90876 BYLU ThinkSystem 2.5" Multi Vendor 3.84TB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A90877 BYLV ThinkSystem 2.5" Multi Vendor 7.68TB Read Intensive SATA 6Gb HS SSD v2 No 12
4XB7A89423 BXDY ThinkSystem 2.5" CM893a 1.92TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A87524 BWKN ThinkSystem 2.5" PM893a 480GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A87525 BWKM ThinkSystem 2.5" PM893a 960GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A87526 BWKL ThinkSystem 2.5" PM893a 1.92TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A87527 BWKK ThinkSystem 2.5" PM893a 3.84TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A87528 BYLK ThinkSystem 2.5" PM893a 7.68TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82258 BQ1Q ThinkSystem 2.5" 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82259 BQ1P ThinkSystem 2.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82260 BQ1R ThinkSystem 2.5" 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82261 BQ1X ThinkSystem 2.5" 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82262 BQ1S ThinkSystem 2.5" 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82263 BQ1T ThinkSystem 2.5" 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A72438 BM8B ThinkSystem 2.5" PM893 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72439 BM8A ThinkSystem 2.5" PM893 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72440 BM89 ThinkSystem 2.5" PM893 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72441 BM88 ThinkSystem 2.5" PM893 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72442 BM87 ThinkSystem 2.5" PM893 7.68TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17072 B99D ThinkSystem 2.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17101 BA7G ThinkSystem 2.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17102 BA7H ThinkSystem 2.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17103 BA7J ThinkSystem 2.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17104 BK77 ThinkSystem 2.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17105 BK78 ThinkSystem 2.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A38271 BCTC ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38272 BCTD ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38273 BCTE ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38274 BCTF ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38275 BCTG ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38141 BE29 ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD SED Support 12
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17080 B8J2 ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38185 B9AC ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38144 B7EW ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38145 B7EX ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38146 B7EY ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A10247 B498 ThinkSystem 2.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10248 B499 ThinkSystem 2.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10249 B49A ThinkSystem 2.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A13622 B49B ThinkSystem 2.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A13623 B49C ThinkSystem 2.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD No 12
Table 37. 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A91175 BZEH ThinkSystem 2.5 U.2 9400 MAX 25.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD (Non-SED) No 10*
4XB7A17129 BNEG ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A17130 BNEH ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A17133 BNEZ ThinkSystem 2.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A17136 BA4V ThinkSystem 2.5" U.2 P5620 12.8TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A17152 BCFV ThinkSystem 2.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10*
4XB7A17153 BCFR ThinkSystem 2.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10*
4XB7A17154 BCFS ThinkSystem 2.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10*
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A79639 BNF1 ThinkSystem 2.5" U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13967 BNEJ ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13970 BNEY ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13971 BNEL ThinkSystem 2.5" U.3 7450 MAX 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A84056 BRG0 ThinkSystem 2.5" U.3 7450 MAX 12.8TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A64175 BE03 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD No 10*
4XB7A17112 B96Z ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10*
4XB7A17113 B96T ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10*
4XB7A17114 B96P ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10*
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A90099 BXMB ThinkSystem 2.5" U.2 PM9A3 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A90100 BXMA ThinkSystem 2.5" U.2 PM9A3 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A90101 BXM9 ThinkSystem 2.5" U.2 PM9A3 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13941 BMGD ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13942 BMGE ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13943 BNEF ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A13631 BNEQ ThinkSystem 2.5" U.2 P5520 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A17145 BCFT ThinkSystem 2.5" U.2 P5500 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10*
4XB7A17146 BCFW ThinkSystem 2.5" U.2 P5500 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10*
4XB7A17147 BCFU ThinkSystem 2.5" U.2 P5500 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10*
4XB7A38196 BC4Y ThinkSystem U.2 PM1733 1.92TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10*
4XB7A38197 BC4Z ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10*
4XB7A38283 BE2E ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10*
4XB7A38284 BE2F ThinkSystem U.2 PM1733 15.36TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10*
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A91176 BZC1 ThinkSystem 2.5" U.3 6500 ION 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A81951 BPKX ThinkSystem 2.5" U.3 PM1733a 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A81952 BPKY ThinkSystem 2.5" U.3 PM1733a 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A81953 BPKZ ThinkSystem 2.5" U.3 PM1733a 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A81954 BPL0 ThinkSystem 2.5" U.3 PM1733a 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A81999 BPL1 ThinkSystem 2.5" U.3 PM1733a 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A79646 BNF3 ThinkSystem 2.5" U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A79647 BNF2 ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A79648 BNF5 ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A79649 BNF4 ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*
4XB7A83097 BQAV ThinkSystem 2.5" U.3 7450 PRO 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10*

* All NVMe drives, with the exception of PM983 drives, are only supported in the front drive bays due to thermal requirements

Table 38. 2.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A13936 B589 ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A13937 B58A ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A13938 B58B ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A08516 B21W ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10*
4XB7A08517 B21X ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10*
4XB7A08518 B21Y ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10*
4XB7A08519 B2XJ ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10*
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A10204 B58G ThinkSystem 2.5" U.2 P4510 2.0TB Read Intensive NVMe PCIe 3.0 x4 HS SSD No 10*
4XB7A10205 B58H ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A08513 B58J ThinkSystem U.2 Intel P4510 8.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10*
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 16
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 16
4XB7A10177 B4D3 ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 16

* All NVMe drives, with the exception of PM983 drives, are only supported in the front drive bays due to thermal requirements

Table 39. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00063 B1JJ ThinkSystem 3.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 4
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00040 AUUC ThinkSystem 3.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 4
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A17222 BCM2 ThinkSystem SR635 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00046 AUUG ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A17223 BCM6 ThinkSystem SR635/SR655 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A17224 BCM4 ThinkSystem SR635/SR655 3.5" 14TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A13911 B7EZ ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A76340 BHX6 ThinkSystem SR635/SR645/SR655 3.5" 18TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A80353 BPKU ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A83766 BTR7 ThinkSystem 3.5" 22TB 7.2K SAS 12Gb Hot Swap 512e HDD Support 4
3.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00047 AUUH ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD FIPS Support 4
7XB7A00048 B0YP ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 4
Table 40. 3.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00052 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A17225 BCM7 ThinkSystem SR635 3.5" 8TB 7.2K SATA 12Gb Hot Swap 512e HDD No 4
7XB7A00054 AUUB ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A17226 BCM5 ThinkSystem SR635/SR655 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A38184 BCM3 ThinkSystem SR635/SR655 3.5" 14TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A13914 B7F0 ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A76341 BHX5 ThinkSystem SR635/SR645/SR655 3.5" 18TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A80354 BPKV ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A83765 BTR8 ThinkSystem 3.5" 22TB 7.2K SATA 6Gb Hot Swap 512e HDD Support 4
Table 41. 3.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80344 BNW7 ThinkSystem 3.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80345 BNWA ThinkSystem 3.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80346 BNWB ThinkSystem 3.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80347 BP3G ThinkSystem 3.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 4
3.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80324 BNWD ThinkSystem 3.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80325 BNWG ThinkSystem 3.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80326 BNWH ThinkSystem 3.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80327 BP3F ThinkSystem 3.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80328 BP3H ThinkSystem 3.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 4
Table 42. 3.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A83218 BR0W ThinkSystem 3.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD Support 4
4XB7A83219 BR0V ThinkSystem 3.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD Support 4
4XB7A83220 BR0U ThinkSystem 3.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD Support 4
4XB7A83221 BR0T ThinkSystem 3.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD Support 4
4XB7A70011 BG03 ThinkSystem 3.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70010 BG02 ThinkSystem 3.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70009 BG01 ThinkSystem 3.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70008 BG00 ThinkSystem 3.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10234 B4Y8 ThinkSystem 3.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10235 B4Y9 ThinkSystem 3.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10236 B4YA ThinkSystem 3.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17066 B8HT ThinkSystem 3.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17043 B8JN ThinkSystem 3.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17067 B8JK ThinkSystem 3.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17068 B8JG ThinkSystem 3.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A17058 B91E ThinkSystem 3.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 4
4XB7A17059 BEVK ThinkSystem 3.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 4
Table 43. 3.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A90888 BYM3 ThinkSystem 3.5" Multi Vendor 480GB Mixed Use SATA 6Gb HS SSD v2 No 4
4XB7A90889 BYM7 ThinkSystem 3.5" Multi Vendor 960GB Mixed Use SATA 6Gb HS SSD v2 No 4
4XB7A90890 BYM8 ThinkSystem 3.5" Multi Vendor 1.92TB Mixed Use SATA 6Gb HS SSD v2 No 4
4XB7A90891 BYLX ThinkSystem 3.5" Multi Vendor 3.84TB Mixed Use SATA 6Gb HS SSD v2 No 4
4XB7A87202 BURK ThinkSystem 3.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD Support 4
4XB7A17137 BA4W ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17138 BA4X ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17139 BA4Y ThinkSystem 3.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17140 BK7P ThinkSystem 3.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17096 B8JL ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17097 B8JF ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17098 B8J0 ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17099 B8HR ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17100 B8HX ThinkSystem 3.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10243 B48E ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10244 B48F ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A90878 BYLW ThinkSystem 3.5" Multi Vendor 240GB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A90879 BYLJ ThinkSystem 3.5" Multi Vendor 480GB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A90880 BYLY ThinkSystem 3.5" Multi Vendor 960GB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A90881 BYLZ ThinkSystem 3.5" Multi Vendor 1.92TB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A90882 BYM0 ThinkSystem 3.5" Multi Vendor 3.84TB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A90883 BYM1 ThinkSystem 3.5" Multi Vendor 7.68TB Read Intensive SATA 6Gb HS SSD v2 No 4
4XB7A17118 BA7K ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17119 BA7L ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17120 BA7M ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17121 BA7N ThinkSystem 3.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17122 BK7F ThinkSystem 3.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17123 BK7G ThinkSystem 3.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A38276 BCTH ThinkSystem 3.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38277 BCTJ ThinkSystem 3.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38278 BCTK ThinkSystem 3.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38279 BCTL ThinkSystem 3.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38281 BCTM ThinkSystem 3.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17081 B8JB ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17082 B8J9 ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17083 B8JC ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17084 B8HZ ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17085 B8HQ ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17086 B8J3 ThinkSystem 3.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10158 B2X7 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10159 B2X8 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10160 B2X9 ThinkSystem 3.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
Table 44. M.2 SATA drives
Part number Feature
code
Description SED
support
Max
Qty
M.2 SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A89422 BYF7 ThinkSystem M.2 ER3 240GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A90049 BYF8 ThinkSystem M.2 ER3 480GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A90230 BYF9 ThinkSystem M.2 ER3 960GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A90105 BXMK ThinkSystem M.2 ER2 240GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A90106 BXMJ ThinkSystem M.2 ER2 480GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A82286 BQ1Z ThinkSystem M.2 5400 PRO 240GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A82287 BQ1Y ThinkSystem M.2 5400 PRO 480GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A82288 BQ20 ThinkSystem M.2 5400 PRO 960GB Read Intensive SATA 6Gb NHS SSD Support 2
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD No 2
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD No 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A14048 B5UP ThinkSystem M.2 5100 960GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A17074 B8JJ ThinkSystem M.2 5300 960GB SATA 6Gbps Non-Hot Swap SSD No 2

Internal backup units

The server does not supports any internal backup units, such as tape drives or RDX drives. External backup units are available as described in the External backup units section.

Optical drives

The server supports the external USB optical drive listed in the following table.

Table 45. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

I/O expansion

The server supports a total of up to 4 PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter or HBA) plus a dedicated OCP 3.0 SFF slot for networking. Slot availability is based on riser selection.

  • Slot 1: PCIe 4.0 x16 LP or FHHL
  • Slot 2: PCIe 4.0 x16 LP (not present if slot 1 is FHHL or rear drive bays are present)
  • Slot 3: PCIe 4.0 x16 LP (not present if rear drive bays are present)
  • Slot 4: PCIe 4.0 x8 LP (internal slot; physically a x16 slot)

The following figure shows the locations of the rear-accessible slots for each configuration selection. The OCP slot in located in the lower-left corner.

SR635 slots
Figure 11. SR635 slots

The slots and riser cards are as follows:

  • Riser 1: Slot 1 (PCIe x16)
    • Slot 1: Low Profile or FHHL, PCIe 4.0 x16 slot
  • Riser 2: Slots 2 & 3 (each PCIe x16)
    • Slot 2: Low Profile, PCIe 4.0 x16 (only available in 3x LP slot configuration)
    • Slot 3: Low Profile, PCIe 4.0 x16 (not available in configurations with rear drive bays)
  • Internal Riser: Slot 4 (PCIe x8)
    • Low Profile PCIe 4.0 x8 slot for internal drive controller (physically a x16 slot)

The riser cards and slot brackets used to provide the above slot combinations in configure-to-order (CTO) configurations are listed in the following table.

Tip: It is also possible to not have any slot selections, in which case slot fillers will be derived in the configurator. Slots can be added later as field upgrades using option part numbers.

Table 46. Riser slot selections - Feature codes for CTO
Feature
code
Description Maximum
Supported
Purpose
Riser 1
B5VV ThinkSystem SR635/SR655 x16 PCIe Riser1 1 Riser for slot 1
B5WZ ThinkSystem SR635/SR655 MS FH Riser BKT 1 FHHL slot bracket for slot 1
B5WD ThinkSystem SR635 MS LP Riser BKT Slot1 1 Low Profile slot bracket for slot 1
Riser 2
B5W0 ThinkSystem SR635/SR655 x16/x16 PCIe Riser2 (BF) 1 Riser for slots 2 & 3
B5X4 ThinkSystem SR635 MS LP+LP BF Riser BKT 1 Low Profile brackets for slots 2 & 3
B715 ThinkSystem SR635 MS LP Riser BKT Slot3 1 Low Profile bracket for slot 3
Internal
B5VW ThinkSystem SR635/SR655 x8 PCIe Internal Riser 1 Riser for Internal slot
B5WN ThinkSystem SR635/SR655 Internal Riser BKT 1 Internal slot bracket

Slot configurations can also be ordered as field upgrades using option part numbers, as listed in the following table.

Table 47. Field upgrades for PCIe slots
Part number Description Maximum
Supported
4XH7A09835

ThinkSystem SR635/SR655 x16 PCIe 1U Riser 1 Kit

  • PCIe 4.0 x16 riser card, installs in riser slot 1, one x16 slot
  • Bracket for slot 1 as a FHHL slot
  • Bracket for slot 1 as a Low Profile slot
1
4XH7A09836

ThinkSystem SR635/SR655 x16/x16 PCIe Riser2 LP Kit

  • PCIe 4.0 x16 riser card, installs in riser slot 2, with two x16 slots
  • Bracket for slots 2 & 3 (use if slot 1 is a LP slot) ("butterfly" bracket)
  • Bracket for slot 3 only (use if slot 1 is a FHHL slot; slot 2 is inaccessible)
1
4XH7A09843

ThinkSystem SR635/SR655 x8 PCIe Internal Riser Kit

  • PCIe 4.0 x8 riser for internal slot
  • Low profile riser bracket for internal slot
  • 2x supercap brackets
1

Network adapters

The server has a dedicated OCP 3.0 SFF slot with PCIe 4.0 x16 host interface. See Figure 3 for the location of the OCP slot.

The following table lists the supported OCP adapters. One port can optionally be shared with the ASPEED management processor for Wake-on-LAN and NC-SI support. Only 1 OCP card can be installed in the server.

Table 48. Supported OCP adapters
Part number Feature code Description
Gigabit
4XC7A08235 B5T1 ThinkSystem Broadcom 5719 1GbE RJ45 4-port OCP Ethernet Adapter
4XC7A08277 B93E ThinkSystem Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter
10 GbE
4XC7A08236 B5ST ThinkSystem Broadcom 57416 10GBASE-T 2-port OCP Ethernet Adapter
4XC7A08239 B5SS ThinkSystem Broadcom 57416 10GBASE-T 2-port + 5720 1GbE 2-port OCP Ethernet Adapter
4XC7A08240 B5T4 ThinkSystem Broadcom 57454 10GBASE-T 4-port OCP Ethernet Adapter
4XC7A08278 BCD5 ThinkSystem Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter
4XC7A80268 BPPY ThinkSystem Intel X710-T4L 10GBase-T 4-Port OCP Ethernet Adapter
4XC7A08310 BB8U ThinkSystem Marvell QL41132 10GBASE-T 2-port OCP Ethernet Adapter
25 GbE
4XC7A08237 B5SZ ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet Adapter
4XC7A08242 B5SV ThinkSystem Broadcom 57454 10/25GbE SFP28 4-port OCP Ethernet Adapter
4XC7A08294 BCD4 ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port OCP Ethernet Adapter
4XC7A80269 BP8L ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-Port OCP Ethernet Adapter
4XC7A08246 B5T2 ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port OCP Ethernet Adapter
4XC7A62582 BE4T ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port OCP Ethernet Adapter
4XC7A08264 B5SW ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port OCP Ethernet Adapter

Installation & removal: Before installing or removing an OCP adapter, power off your server and disconnect power cords first. See Support tip HT509768 for details.

For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet

The following table lists additional supported network adapters that can be installed in the regular PCIe slots.

Table 49. Supported PCIe Network Adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00484 AUZV ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter 1, 3, 2 3
7ZT7A00482 AUZX ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter 1, 3, 2 3
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter 1, 3, 2* 3
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter 1, 3, 2 3
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 1, 3, 2 3
10 GbE
7ZT7A00496 AUKP ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter 1, 3, 2 3
4XC7A08245 B5SU ThinkSystem Broadcom 57454 10GBASE-T 4-port PCIe Ethernet Adapter 1, 3, 2* 3
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 1, 3, 2 3
7ZT7A00537 AUKX ThinkSystem Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 1, 3, 2* 3
4XC7A80266 BNWL ThinkSystem Intel X710-T2L 10GBase-T 2-Port PCIe Ethernet Adapter 1, 3, 2 3
4XC7A79699 BMXB ThinkSystem Intel X710-T4L 10GBase-T 4-Port PCIe Ethernet Adapter 1, 3, 2 3
4XC7A08225 B31G ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter 1, 3, 2 3
25 GbE
4XC7A08238 B5T0 ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter 1, 3, 2* 3
4XC7A08316 BD49 ThinkSystem Broadcom 57454 10/25GbE SFP28 4-port PCIe Ethernet Adapter V2 1* 1†
4XC7A08295 BCD6 ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 1, 3, 2* 3
4XC7A80267 BP8M ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-Port PCIe Ethernet Adapter 1 1†
4XC7A08270 B652 ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 1, 3, 2* 3
4XC7A08249 B653 ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter 1, 3, 2* 3
4XC7A62580 BE4U ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 1, 3, 2* 3
100 GbE
4XC7A08297 BK1J ThinkSystem Broadcom 57508 100GbE QSFP56 2-port PCIe 4 Ethernet Adapter 1, 3, 2* 3**
4XC7A08248 B8PP ThinkSystem Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe Ethernet Adapter 1, 3, 2* 3**
InfiniBand
4C57A14177 B4R9 ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter 1, 3, 2* 3**
4C57A14178 B4RA ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter 1, 3, 2* 3**
4C57A15326 B4RC ThinkSystem Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter 1, 3, 2* 3**

* Not supported in slot 2 when a 280W processor is installed
** See thermal requirements below
† In the SR635, this adapter requires a full-height bracket and must be installed in a full-height slot. The use of a low-profile bracket and slot is not supported.

The following thermal requirement apply to HDR/HDR100 InfiniBand and 100/200Gb Ethernet adapters:

  • The high performance cooling fans must be installed. See the Cooling section for details.
  • Ambient temperature cannot be greater than 35°C (if the processor TDP is 155W or lower) or 30°C (for 180W or higher processors)

For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet

Fibre Channel host bus adapters

The following table lists the Fibre Channel HBAs supported by the SR635.

Note that the Emulex LPe35000 adapters are supported either with EPYC 7002 "Rome" processors or with EPYC 7003 "Milan" processors, as indicated in the table.

Table 50. Fibre Channel HBAs
Part
number
Feature
code
Description EPYC
7002
EPYC
7003
Slots
supported
Maximum
supported
32 Gb Fibre Channel HBAs
4XC7A08250 B5SX ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter Yes No 1, 3, 2* 3
4XC7A08251 B5SY ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter Yes No 1, 3, 2* 3
4XC7A76498 BJ3G ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter v2 No Yes 1, 3, 2* 3
4XC7A76525 BJ3H ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter V2 No Yes 1, 3, 2* 3
4XC7A08279 BA1G ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel Adapter Yes Yes 1, 3, 2* 3
4XC7A08276 BA1F ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel Adapter Yes Yes 1, 3, 2* 3
7ZT7A00516 AUNS ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter Yes Yes 1, 3, 2* 3
7ZT7A00518 AUNU ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter Yes Yes 1, 3, 2* 3
16 Gb Fibre Channel HBAs
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA Yes Yes 1, 3, 2* 3
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA Yes Yes 1, 3, 2* 3
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA Yes Yes 1, 3, 2* 3
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA Yes Yes 1, 3, 2* 3

* Not supported in slot 2 when a 280W processor is installed

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba

SAS adapters for external storage

The following table lists SAS HBAs and RAID adapters supported by SR635 server for use with external storage.

Table 51. Adapters for external storage
Part
number
Feature
code
Description Slots
supported
Maximum
supported
SAS HBAs
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA 1, 3, 2 3
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA 1, 3, 2 3
4Y37A78837 BNWK ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA 1, 3, 2 3
4Y37A09724 B8P7 ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA 1, 3, 2 3
External RAID adapters
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 1, 3, 2 3*
4Y37A78836 BNWJ ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter 1, 3, 2 3*

* See configuration rules below

Mixing storage adapter families: The following HBA/RAID adapter combinations are supported:

  • X30 external adapters with other X30 adapters (internal or external)
  • X40 external adapters with other X40 adapters (internal or external)
  • X40 external adapters with X350 internal adapters

The following HBA/RAID adapter combinations are not supported:

  • X30 adapters (internal or external) with X40 adapters (internal or external)
  • X30 adapters (internal or external) with X350 internal adapters

Configuration rules

The RAID 930-8e and RAID 940-8e use a flash power module (supercap), which can be installed in one of 3 locations as shown in the following figure.

Location of all three supercaps
Figure 12. Location of all three supercaps in the SR635 (2.5-inch drive configuration)

The number of supercap locations is reduced depending on installed components:

  • For configurations with 2.5-inch front drives and no mid drive cage, 3x 930/940-8e adapters and supercaps can be installed (locations 1, 2, and 3).
  • For configurations with 2.5-inch front drives and a mid drive cage installed, 1x 930/940-8e adapter and supercap can be installed (location 3 only).
  • For configurations with 3.5-inch front drives, and no mid drive cage, 2x 930/940-8e adapters and supercaps can be installed (location 1 and 2; location 3 is not present).
  • For configurations with 3.5-inch front drives and a mid drive cage installed, no 930/940-8e adapters and supercaps can be installed.
  • If any internal RAID adapters with flash power modules are installed, the maximum number of 930/940-8e adapters supported is further reduced by that number.

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters and RAID adapters categories:
https://lenovopress.com/servers/options/hba
https://lenovopress.com/servers/options/raid

The following table compares the specifications of the external SAS HBAs and RAID adapters.

Table 52. Comparison of external storage adapters
Feature 430-8e 430-16e 930-8e
Adapter type HBA HBA External RAID
Part number 7Y37A01090 7Y37A01091 7Y37A01087
Controller chip LSI SAS3408 LSI SAS3416 LSI SAS3516
Broadcom equivalent HBA 9400-8e HBA 9400-16e MegaRAID 9480-8e
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 16 8
Port connectors 2x Mini-SAS HD SFF8644 4x Mini-SAS HD SFF8644 2x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS/SATA SAS,SATA
Drive type HDD/SSD/SED* HDD/SSD/SED* HDD,SED,SSD
Hot-swap drives Yes Yes Yes
Maximum devices 1024 1024 216
RAID levels None None 0/1/10/5/50/6/60
JBOD mode Yes Yes Yes
Cache None None 4GB (Standard)
CacheVault cache protection None None Yes (Flash)
Performance Accelerator (FastPath) No No Yes
SSD Caching (CacheCade Pro 2.0) No No No
SED support* Yes Yes Yes

* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.

Flash storage adapters

The SR635 supports the PCIe Flash Storage adapters listed in the following table.

Table 53. Flash Storage Adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Mainstream NVMe PCIe Adapters - Optimized for mixed-intensive application workloads with an endurance of 3-5 DWPD.
4XB7A38234 BCGJ ThinkSystem HHHL Kioxia CM5-V 1.6TB Mainstream NVMe PCIe3.0 x4 Flash Adapter 1, 3, 2 3
4XB7A38237 BCGK ThinkSystem HHHL Kioxia CM5-V 3.2TB Mainstream NVMe PCIe3.0 x4 Flash Adapter 1, 3, 2 3
4XB7A38240 BCGL ThinkSystem HHHL Kioxia CM5-V 6.4TB Mainstream NVMe PCIe3.0 x4 Flash Adapter 1, 3, 2 3
4XB7A14075 B8JH ThinkSystem HHHL PM1735 1.6TB Mainstream NVMe PCIe 4.0 x8 Flash Adapter 1, 3, 2 3
4XB7A14076 B8HW ThinkSystem HHHL PM1735 3.2TB Mainstream NVMe PCIe 4.0 x8 Flash Adapter 1, 3, 2 3
4XB7A14077 B96M ThinkSystem HHHL PM1735 6.4TB Mainstream NVMe PCIe4.0 x8 Flash Adapter 1, 3, 2 3
4XB7A08520 B32L ThinkSystem HHHL Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1, 3, 2 3
4XB7A08521 B32M ThinkSystem HHHL Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1, 3, 2 3

For details about these adapters, see the Lenovo Press product guides in the Flash Adapters category:
https://lenovopress.com/servers/options/ssdadapter

Configuration rules

The following configuration requirements must be met when installing flash storage adapters:

  • GPU adapters are not supported
  • Maximum processor TDP is 155W
  • Performance fans are required and will be derived by the configurator for configure-to-order builds.
  • When adding Flash adapters as field upgrades, you will be required to replace all standard fans with performance fan modules. The ordering part number is listed in the following table - you will be required to order 7 fans.
Table 54. Performance fan ordering information
Part number Feature code Description Quantity
required
4F17A14483 B5X0 ThinkSystem SR635 Performance Fan Module 7

GPU adapters

The SR635 supports the following graphics processing units (GPUs).

Table 55. Supported GPUs
Part
number
Feature
code
Description Slots
supported
Maximum
supported
4X67A81547 BP05 ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU 1, 3, 2 3
CTO only BQZT ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU w/o CEC 1, 3, 2 3
4X67A14926 B4YB ThinkSystem NVIDIA T4 16GB PCIe Passive GPU 1, 3, 2 3
4X67A11584 B31D ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU 1, 3, 2 3

For information about these GPUs, see the ThinkSystem GPU Summary, available at:
https://lenovopress.com/lp0768-thinksystem-thinkagile-gpu-summary

Configuration rules

The following configuration requirements must be met when installing GPUs:

  • Some NVIDIA A Series GPUs are available as two feature codes, one with a CEC chip and one without a CEC chip (ones without the CEC chip have "w/o CEC" in the name). The CEC is a secondary Hardware Root of Trust (RoT) module that provides an additional layer of security, which can be used by customers who have high regulatory requirements or high security standards. NVIDIA uses a multi-layered security model and hence the protection offered by the primary Root of Trust embedded in the GPU is expected to be sufficient for most customers. The CEC defeatured products still offer Secure Boot, Secure Firmware Update, Firmware Rollback Protection, and In-Band Firmware Update Disable. Specifically, without the CEC chip, the GPU does not support Key Revocation or Firmware Attestation. CEC and non-CEC GPUs of the same type of GPU can be mixed in field upgrades.
  • All GPUs installed must be identical
  • Rear drive bays and mid-chassis drive bays are not supported.
  • Flash storage adapters are not supported.
  • 1100W power supplies (or in some configurations, 750W power supplies) are required.
  • If the intrusion switch is installed, then only two GPUs can be installed, in slots 2 and 3. The intrusion switch and a GPU in slot 1 are mutually exclusive.

Additional rules when installing T4 GPUs:

  • With two GPUs installed, processor TDP greater than 200W not supported
    • If ambient temperature is 35°C, then processor TDP greater than 120W not supported
    • If ambient temperature is 30°C, then processor TDP greater than 200W not supported
  • With three GPUs installed, processor TDP greater than 120W not supported
  • The following additional drive backplane rules apply if 3 GPUs are installed (rules do not apply if only 2 GPUs installed):
    • 3.5-inch drive bay backplane (AUW8) is fully supported
    • 8x 2.5-inch drive backplane (B7K3) supported, however 2 drive bays (6, 7) must be empty
    • 6x 2.5-inch SAS/SATA + 4x AnyBay backplane (AUW9) supported, however all AnyBay bays (6, 7, 8, 9) must be empty
    • 10x 2.5-inch AnyBay backplane (B5VS), however 4 bays (6, 7, 8, 9) must be empty
    • Ambient temperature great than 30°C is not supported
    • Processor TDP greater than 120W is not supported

Additional rules when installing any quantity of P620 GPUs:

  • All front drive bay configurations are supported
  • Ambient temperature great than 35°C is not supported
  • Processor TDP greater than 240W is not supported

GPU field upgrades

When ordering GPUs as part of a CTO configuration, the necessary cooling features are automatically selected as part of the order. However when ordering the GPUs as field upgrades, you will need to also order 7 performance fans which will replace the standard fans already installed. 7 part numbers will need to be ordered per server.

Table 56. Performance fan ordering information
Part number Description Quantity required
4F17A14483 ThinkSystem SR635 Performance Fan Module 7

When a GPU is added as a field upgrade, all empty DIMM slots must have a dummy DIMM blank installed in each DIMM slot, to ensure the optimal air flow. Ordering information is in the following table.

Table 57. ThinkSystem Dummy DIMM Kit
Part number Description Quantity required
4M27A11810 ThinkSystem Dummy DIMM Package Kit
(contains 24 dummy memory DIMMs)
1

Cooling

The SR635 server has seven 40 mm dual-rotor hot-swap variable-speed fans and either 6 or 7 fans are standard depending on the configuration. The fans are dual-rotor counter-rotating units, which means that the fans have two separate propellors, one in front of the other, and that the propellors rotate in opposite directions. The server offers N+1 redundancy. The server also has one additional fan integrated in each of the two power supplies.

Under all of the following conditions, only 6 fans are required:

  • No M.2 Module
  • No internal riser slot
  • No mid drive bays
  • No rear drives
  • No GPUs

For all other configurations, all 7 fans are required.

Table 58. Fan ordering information
Part number Feature code Description Maximum
supported
4F17A12358 B5X1 ThinkSystem SR635 1U Fan Module 7
4F17A14483 B5X0 ThinkSystem SR635 Performance Fan Module 7

Some configurations, such as the use of high-TDP processors, GPUs, flash storage adapters, mid drive or rear drives, or Ethernet/InfiniBand adapters of 100Gb or higher, will require the use of high performance fans which have higher RPMs. For configure-to-order builds, the DCSC configurator will automatically select the required fans. For field upgrades, the option part numbers may include the upgraded components when they are needed, or you may need to order the performance fans separately.

See these sections for details:

Power supplies

The server supports up to two redundant hot-swap power supplies.

The power supply choices are listed in the following table. Both power supplies used in server must be identical.

Tip: Use Lenovo Capacity Planner to determine exactly what power your server needs:
https://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Table 59. Power supply options
Part number Feature
code
Description Maximum
supported
110V AC 220V AC 240V DC
China only
-48V DC
AC power input
7N67A00882 AVWC ThinkSystem 550W(230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes No
7N67A00883 B6XT ThinkSystem 750W(230/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes No
7N67A00884 B6XS ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply 2 No Yes Yes No
4P57A82020 BR1Y ThinkSystem V1 750W (230Vac) Titanium Hot Swap Power Supply 2 No Yes Yes No
7N67A00885 AVWF ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes No
-48V DC input power
4P57A15363* B4Z5* ThinkSystem 1100W -48V DC Power Supply 2 No No No Yes

* -48V DC power supply is only available via Special Bid

Dual-voltage power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. For China customers, all AC power supplies support 240V DC.

All supported AC power supplies have a C14 connector. The -48V DC power supply has a Positronic PLB3W3M1000/AA connector.

Power supply options do not include a line cord.

For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without power cords if desired.

Power cords

Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.

110V customers: If you plan to use the 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 60. Power cords
Part number Feature code Description
Rack cables - C13 to C14
SL67B08593 BPHZ 0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08367 B0N5 1.0m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08368 B0N6 1.5m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable
Rack cables - C13 to C14 (Y-cable)
00Y3046 A4VQ 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047 A4VR 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable
Rack cables - C13 to C20
39Y7938 6204 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable
Rack cables - C13 to C20 (Y-cable)
47C2491 A3SW 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable
47C2492 A3SX 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable
47C2493 A3SY 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable
47C2494 A3SZ 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable
Line cords
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y7928 6210 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
00WH545 6401 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord

For the -48V DC Power Supply, the following power cable is supported.

Table 61. -48V DC power cable
Part number Feature code Description
CTO only B93F ThinkSystem 2.5m,DC Cable

Integrated virtualization

The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/

Systems management

The server contains an integrated service processor which provides advanced control, monitoring, and alerting functions. The service processor is based on the ASPEED AST2500 baseboard management controller (BMC).

Local management

The SR635 offers a front operator panel with key LED status indicators, as shown in the following figure.

Tip: The Network LED only shows network activity of the installed OCP network adapter.

SR635 LED status panel
Figure 13. Front operator panel

The server offers light path diagnostics. If an environmental condition exceeds a threshold or if a system component fails, the ASPEED service processor lights LEDs inside the server to help you diagnose the problem and find the failing part. The SR635 has fault LEDs next to the following components:

  • Each memory DIMM
  • Each drive bay
  • Each system fan
  • Each power supply

The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access the service processor.

Remote management

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (traps and gets)
  • Redfish support to the Redfish Schema 2018.1 (DMTF DSP0266 1.5.0 compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for the device being used - laptop, tablet, phone) with NLS support

Remote connectivity is provided by a dedicated 1Gb Ethernet management port (see the locations of ports at the rear of the server in the Components and connectors section). Remote management can also be performed via the first port of the installed OCP adapter using the shared management capability of the adapter via NC-SI. NC-SI connectivity is 10/100 Mbps Ethernet.

IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.

Table 62. IPMI-over-LAN settings
Part number Feature code Description
CTO only B7XZ Disable IPMI-over-LAN (default)
CTO only B7Y0 Enable IPMI-over-LAN

A virtual presence (iKVM remote control and virtual media) capability also comes standard in the server for remote server management.

The remote control functions include the following:

  • Remotely viewing video with graphics resolutions up to 1920x1080 at 60 Hz and 32 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Full remote administration with seamless access from UEFI POST through to operating system load
  • OS independent - no drivers or OS agents required
  • Support for up to four remote users simultaneously

The remote media functions include:

  • USB 2.0 compliant connectivity
  • Up to four simultaneously mounted diskette, HDD, CD, DVD, USB flash drive, or image files
  • Optional encryption on connections
  • Requires Java Runtime Environment (JRE) 1.4.2 or later
  • Can be used as a boot device
  • Persistent session across system reset (but not across AC power loss)

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to other Lenovo servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

On the SR635, XClarity Administrator v3.2.0 or later is required for full firmware-update support, managed authentication, and remote control. The baseboard management controller firmware should be v3.56 or later.

Lenovo XClarity Administrator supports the following functions on the SR635:

  • Asset management
  • Hardware monitoring
  • Hardware management
  • Configuration management
  • Firmware compliance and updates
  • Device authentication using an LDAP server
  • Remote control
  • Warranty status
  • Automatic problem notification (call home)

For details of these functions, see the paper Introduction to Managing ThinkSystem SR635 and SR655 Servers with Lenovo XClarity Administrator, available from https://lenovopress.com/lp1419

The following functions are not supported:

  • Network interfaces using IPv6 link-Local Address (LLA) (only IPv4 addresses and global unicast IPv6 address are supported)
  • Server configuration other than BIOS configuration using configuration patterns
  • Windows OS device driver updates
  • Operating system deployment
  • Virtually reseating a server
  • Single sign-on to the management controller interface

For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Provisioning Manager Lite

Lenovo XClarity Provisioning Manager Lite (LXPM Lite) v2 is an embedded application for system setup and firmware upgrades. The tool is accessed during system boot by pressing F11 when prompted.

The software tool provides the following functions:

  • Easy-to-use, language-selectable graphical interface
  • Integrated help system
  • Automatic hardware detection
  • Ability to install an operating system and device drivers either in an unattended mode or manually
  • Ability to clone the settings in one server to other similarly configured Lenovo servers
  • Supports RAID setup
  • Diagnostics for memory test, hard disk drive test, and RAID log collection.

The LXPM Lite user interface is shown in the following figure.

Lenovo XClarity Provisioning Manager Lite v2 user interface
Figure 14. Lenovo XClarity Provisioning Manager Lite user interface (pre-production server)

For more information about LXPM Lite, see the following support page:
https://datacentersupport.lenovo.com/us/en/solutions/HT507133

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and drivers. It provides functions to collect full system health information (including health status), configure system settings, update BMC/UEFI firmware (in-band and out-of-band), and update drivers.

    Note: OneCLI on the SR635 currently does not support firmware update of adapters. For UEFI settings, all OneCLI commands are supported. For BMC settings, OneCLI support is limited to network, ntp, dns, account commands and the following VPD parameters: VPD.Model, VPD.SerialNumber, VPD.AssetTag, VPD.UUID.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

    Note: UpdateXpress on the SR635 is currently limited to only support BMC and UEFI firmware updates.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo servers. Using built-in intelligence, it identifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power-saving policies.

Lenovo XClarity Energy Manager offers the following capabilities:

  • Monitors room, row, rack, and device levels in the data center
  • Reports vital server information, such as power, temperature and resource utilization
  • Monitors inlet temperature to locate hot spots, reducing the risk of data or device damage
  • Provides finely-grained controls to limit platform power in compliance with IT policy
  • Generates alerts when a user-defined threshold is reached

Note: In the SR635, system power capping function is not supported on Lenovo XClarity Energy Manager.

Lenovo XClarity Energy Manager is an optional software component that is licensed on a per managed node basis, that is, each managed server requires a license. To manage systems, a node license pack should be purchased. The following table lists the geo-specific Lenovo XClarity Energy Manager software license options.

Table 63. Lenovo XClarity Energy Manager software options
Description Part number
(NA, AP, Japan)*
Part number
(EMEA, LA)**
Quantity
Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S 01DA225 01DA228 1

For more information, refer to the Lenovo XClarity Energy Manager web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The SR635 server offers the following security features:

  • Administrator and power-on password
  • Integrated Trusted Platform Module (TPM) supporting TPM 2.0
  • Optional Nationz TPM 2.0, available only in China (CTO only)
  • Optional chassis intrusion switch (CTO only)
  • Optional lockable front security bezel

The server is NIST SP 800-147B compliant.

The optional lockable front security bezel is shown in the following figure and includes a key that enables you to secure the bezel over the drives and system controls thereby reducing the chance of unauthorized or accidental access to the server.

SR635 lockable front security bezel
Figure 15. Lockable front security bezel

The dimensions of the security bezel are:

  • Width: 437 mm (17.2 in.)
  • Height: 43 mm (1.3 in.)
  • Width: 23 mm (0.9 in.)

The following table lists the security options for the SR635.

Table 64. Security features
Part number Feature code Description
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0 (China customers only)
None* B9V3 ThinkSystem Intrusion Switch Cable
7Z17A02581 AUWR ThinkSystem 1U Security Bezel

* Not available as a field upgrade. The component is CTO or on pre-configured models only.

GPU support with the intrusion switch: If the intrusion switch is selected, then a GPU cannot be installed in slot 1.

Rack installation

The following table lists the rack installation options that are available for the server.

The VGA Upgrade Kit allows you to upgrade your server by adding a VGA video port to the front of the server (if the server does not already come with a front VGA port). When the front VGA is in use, the rear VGA port is automatically disabled.

Table 65. Rack installation options
Option Feature Code Description
Optional front VGA port
4XH7A80465 BMNW or BMNX* ThinkSystem SR635 Front VGA Upgrade Kit v2
(adds a VGA port to the front of the server)
4XH7A09849 AUWU or B5TX* ThinkSystem SR635 Front VGA Upgrade Kit
(adds a VGA port to the front of the server)
4-post rail kits
  B42B ThinkSystem Toolless Friction Rail v2
4M17A13564 BK7W ThinkSystem Toolless Friction Rail v2
7M27A05702 AXCA ThinkSystem Toolless Slide Rail
7M27A05701 AXCB ThinkSystem Toolless Slide Rail Kit with 1U CMA
Cable management arm
7M27A05699 B136 ThinkSystem 1U CMA Upgrade Kit for Toolless Slide Rail

* BMNX / B5TX is a 950mm cable for configurations with 3.5-inch drive bays in the front of the server; BMNW / AUWU is a 715mm cable for configurations with 2.5-inch drive bays in the front of the server. The related option part number contains both cables.

The following table summarizes the rail kit features and specifications.

Table 66. Rail kit features and specifications summary
Feature ThinkSystem Toolless Slide Rail ThinkSystem Toolless Friction Rail v2
Part number 7M27A05702 (optional CMA)
7M27A05701 (with CMA)
4M17A13564
Rail type Full-out slide (ball bearing) Half-out slide (friction)
Toolless installation Yes Yes
Cable Management
Arm (CMA) support
Yes
  • Standard on 7M27A05701
  • For 7M27A05702, use 7M27A05699
No
In-rack server maintenance Yes No
1U PDU support Yes Yes
0U PDU support Limited* Limited**
Rack type Lenovo and IBM 4-post,
IEC standard-compliant
Lenovo and IBM 4-post,
IEC standard-compliant
Mounting holes Square or round Square or round
Mounting flange thickness 2 mm - 3.3 mm
(0.08 - 0.13 in.)
2 mm - 3.3 mm
(0.08 - 0.13 in.)
Distance between front
and rear mounting flanges
610 mm - 864 mm
(24 - 34 in.)
610 mm - 864 mm
(24 - 34 in.)
Rail length*** 730 mm (28.74 in.) 751 mm (29.6 in.)

* For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** For 0U PDU support with the friction rail kit, the rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Rack shipment: The following restriction applies when shipping the SR635 in a rack:

  • No 2.5-inch rear drive bays

Operating system support

The SR635 with EPYC 7003 processors supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 8.9
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • Red Hat Enterprise Linux 9.3
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

The SR635 with EPYC 7002 processors supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 8.9
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • Red Hat Enterprise Linux 9.3
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide:

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 67. VMware ESXi preload
Part number Feature code Description
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed) (EPYC 7002 only)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)
CTO only BBZG VMware ESXi 7.0 (Factory Installed) (EPYC 7002 only)
CTO only BE5E VMware ESXi 7.0 U1 (Factory Installed) (EPYC 7002 only)
CTO only BHSR VMware ESXi 7.0 U2 (Factory Installed)
CTO only BMEY VMware ESXi 7.0 U3 (Factory Installed)
CTO only BMT5 VMware ESXi 8.0 (Factory Installed)
CTO only BQ8S VMware ESXi 8.0 U1 (Factory Installed)
CTO only BYC7 VMware ESXi 8.0 U2 (Factory Installed)

Configuration rule:

  • An ESXi preload cannot be selected if the configuration includes an NVIDIA GPU (ESXi preload cannot include the NVIDIA driver)

Physical and electrical specifications

The SR635 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:

  • Width: 440 mm (17.3 inches)
  • Height: 43 mm (1.7 inches)
  • Depth: 755 mm (29.7 inches)

The following table lists the detailed dimensions. See the figure below for the definition of each dimension.

Table 68. Detailed dimensions
Dimension Description
482 mm Xa = Width, to the outsides of the front EIA flanges
435 mm Xb = Width, to the rack rail mating surfaces
440 mm Xc = Width, to the outer most chassis body feature
43 mm Ya = Height, from the bottom of chassis to the top of the chassis
714 mm Za = Depth, from the rack flange mating surface to the rearmost I/O port surface
721 mm Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body
743 mm Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle
35 mm Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface
47 mm Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface

Rack server dimensions
Figure 16. Server dimensions

The shipping dimensions (cardboard packaging) of the SR635 are as follows:

  • Width: 587 mm (23.1 inches)
  • Height: 225 mm (8.9 inches)
  • Depth: 998 mm (39.3 inches)

The server has the following weight:

  • Maximum weight: 19.2 kg (42.3 lb)

Electrical specifications for AC power supplies:

  • Electrical - Input voltage
    • 100 - 127 (nominal) V AC, 50 Hz or 60 Hz
    • 200 - 240 (nominal) V AC, 50 Hz or 60 Hz
    • 180 - 300 V DC (China only)
  • Inlet current:
    • 100-127 V:
      • 550W power supply: 6.2 A
      • 750W power supply: 8.4 A
      • 1100W power supply: 12 A
    • 200-240 V:
      • 550W power supply: 3.0 A
      • 750W power supply: 4.1 A
      • 1100W power supply: 6 A

Electrical specifications for DC input power supply:

  • Input voltage: -48 to -60 Vdc
  • Inlet current (1100W power supply): 26 A

Operating environment

The ThinkSystem SR635 server complies with ASHRAE Class A2 specifications with most configurations, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.

The restrictions to ASHRAE A2 support are as follows:

  • The use of a processor with a TDP of 225W or higher requires the ambient temperature be no more than 30°C
  • The use of Two GPUs and a processor with a TDP higher than 120W requires the ambient temperature be no more than 30°C
  • The use of Three GPUs requires the ambient temperature be no more than 30°C
  • The use of Mid drive bays requires the ambient temperature be no more than 30°C
  • The use of Rear drive bays requires the ambient temperature be no more than 30°C
  • The use of Ethernet/InfiniBand adapters of 100Gb or 200Gb, combined with the use of a processor with a TDP of 180W or higher, requires the ambient temperature be no more than 30°C

To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements:

  • Processor TDP greater than 155W not supported
  • No support for 10x 2.5" front drive bays (the 4x 3.5-inch and 8x 2.5-inch bay configurations are supported)
  • No support for NVMe drives
  • No support for rear drive bays or mid drive bays
  • No support for GPUs
  • No support for M.2
  • No support for PCIe flash storage adapters
  • No support for OCP networking adapters of 10GbE or faster
  • No support for Ethernet adapters of 10GbE or faster
  • No support for DIMMs of 128GB or larger capacity
  • Advanced heatsink (feature B5UR) and performance fans (feature B5X0) must be configured

Temperature and humidity

The server is supported in the following environment:

  • Air temperature:
    • Operating:
      • ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
    • Server off: 5°C to 45°C (41°F to 113°F)
    • Shipment/storage: -40°C to 60°C (-40°F to 140°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating
      • ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
      • ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
      • ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
    • Shipment/storage: 8% to 90% 

Heat output

The server generates the following heat:

  • Heat/thermal output:
    • Minimum configuration: 346 BTU/hr, 101 W
    • Maximum configuration: 3197 BTU/hr, 937 W

Acoustical noise emissions

The server has the following acoustic noise emissions declaration:

  • Sound power level (LWAd):
    • Idling: 5.7 Bel (typical), 7.0 Bel (Storage rich), 7.0 Bel (GPU rich)
    • Operating: 5.9 Bel (typical), 7.2 Bel (storage rich), 8.5 Bel (GPU rich)
  • Sound pressure level (LpAm):
    • Idling: 41 dBA (Typical), 54 dBA (Storage rich), 54 dBA (GPU rich)
    • Operating: 43 dBA (Typical), 56 dBA (Storage rich), 69 dBA (GPU rich)

Notes:

  • The sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
  • The declared acoustic sound levels are based on the following configurations, which may change slightly depending on configuration/conditions:
    • Typical: 1x 155W CPU, 8x 32GB RDIMM, 8x 2.5" HDD, 530-8i RAID, X710-T2L OCP, 2x 750W PSU
    • Storage rich: 1x 155W CPU, 16x 64GB RDIMM, 16x NVMe, 10GBASE-T 4-port PCIe Ethernet Adapter, 2x 750W PSU   
    • GPU rich: 1x 155W CPU, 16x 64GB RDIMM, 10x 2.5" HDD, 930-16i RAID, 10GBASE-T 4-port PCIe Ethernet Adapter, 2x T4 GPU, 2x 1100W PSU

Shock and vibration

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces

Particulate contamination

Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might damage the system that might cause the system to malfunction or stop working altogether.

The following specifications indicate the limits of particulates that the system can tolerate:

  • Reactive gases:
    • The copper reactivity level shall be less than 200 Angstroms per month (Å/month)
    • The silver reactivity level shall be less than 200 Å/month
  • Airborne particulates:
    • The room air should be continuously filtered with MERV 8 filters.
    • Air entering a data center should be filtered with MERV 11 or preferably MERV 13 filters.
    • The deliquescent relative humidity of the particulate contamination should be more than 60% RH
    • Environment must be free of zinc whiskers

For additional information, see the Specifications section of the documentation for the server, available from the Lenovo Documents site, https://pubs.lenovo.com/

Warranty and Support

The SR635 has a 1-year or 3-year warranty based on the machine type of the system:

  • 7Y98 - 1 year warranty
  • 7Y99 - 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Regulatory compliance

The SR635 server conforms to the following standards:

  • Energy Star 3.0
  • FCC: Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • China CCC (GB4943.1), GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN32, Class A; KN35
  • Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011(for Safety); TP TC 020/2011(for EMC)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 32, Class A
  • TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
  • India BIS certification

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 69. External drive enclosures
Model Description
4587HC1 Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays)
4587HC2 Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays)
6413HC1 Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays)
7DAHCTO1WW Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays)

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The server supports both USB-attached RDX backup units and SAS-attached tape drives.

The following table lists the available external SAS tape backup options.

Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic

Table 70. External SAS backup options
Part number Description
External SAS tape backup drives
6160S6E IBM TS2260 Tape Drive Model H6S
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
6160S9E IBM TS2290 Tape Drive Model H9S
External SAS tape backup autoloaders
6171S6R IBM TS2900 Tape Autoloader w/LTO6 HH SAS
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
SAS backup drives for TS4300 Tape Library
01KP934 LTO 6 HH SAS Drive
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive
02JH836 LTO 9 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

The following table lists the external RDX backup options available.

Table 71. External RDX dock and cartridges
Part number Feature code Description
External RDX docks
4T27A10725 B32R ThinkSystem RDX External USB 3.0 Dock (No cartridge included with the drive)
Cartridges
7TP7A01601 AVF8 ThinkSystem RDX 500GB Cartridge
7TP7A01602 AVF1 ThinkSystem RDX 1TB Cartridge
7TP7A01603 AVF0 ThinkSystem RDX 2TB Cartridge
7TP7A04318 AXD1 ThinkSystem RDX 4TB Cartridge

For more information, see the Lenovo RDX USB 3.0 Disk Backup Solution product guide:
https://lenovopress.com/tips0894-rdx-usb-30

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 72. Ethernet LAN switches
Part number Description
1 Gb Ethernet Rack switches
7Y810011WW Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front)
7Z320O11WW Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE)
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
1 Gb Ethernet Campus switches
7Z340011WW Lenovo CE0128TB Switch (3-Year Warranty)
7Z360011WW Lenovo CE0128TB Switch (Limited Lifetime Warranty)
7Z340012WW Lenovo CE0128PB Switch (3-Year Warranty)
7Z360012WW Lenovo CE0128PB Switch (Limited Lifetime Warranty)
7Z350021WW Lenovo CE0152TB Switch (3-Year Warranty)
7Z370021WW Lenovo CE0152TB Switch (Limited Lifetime Warranty)
7Z350022WW Lenovo CE0152PB Switch (3-Year Warranty)
7Z370022WW Lenovo CE0152PB Switch (Limited Lifetime Warranty)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7Z330O11WW Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
7Z210O21WW Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE)
7Z330O21WW Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)
7Z210O11WW Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 73. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 74. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The following table lists the supported rack cabinets.

Table 75. Rack cabinets
Part number Description
93072RX 25U Standard Rack (1000mm)
93072PX 25U Static S2 Standard Rack (1000mm)
7D6DA007WW ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WW ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O42 Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410-P42 Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93074RX 42U Standard Rack (1000mm)
7D6EA009WW ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWW ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O48 Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410-P48 Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM console options

The following table lists the supported KVM consoles.

Table 76. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 77. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 78. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Partner Technical Webinar - ISG Portfolio Update
    2024-04-15 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - ISG Portfolio Update

    In this 60-minute replay, Mark Bica, NA ISG Server Product Manager reviewed the Lenovo ISG portfolio. He covered new editions such as the SR680a \ SR685a, dense servers, and options that are strategic for any workload.

    Published: 2024-04-15
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 041224
  2. Partner Technical Webinar – StorMagic
    2024-03-19 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar – StorMagic

    March 08, 2024 – In this 60-minute replay, Stuart Campbell and Wes Ganeko of StorMagic joined us and provided an overview of StorMagic on Lenovo. They also demonstrated the interface while sharing some interesting use cases.

    Published: 2024-03-19
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 030824
  3. Intel Transparent Supply Chain on Lenovo Servers
    2024-01-29 | 12 minutes | Employees and Partners
    Details
    Intel Transparent Supply Chain on Lenovo Servers

    This course introduces the Intel Transparent Supply Chain (TSC) program, explains how the program works, and discusses the benefits of the Intel TSC program to customers. Adding the Intel TSC feature to an order is explained.

    Course objectives:
    • Describe the Intel® Transparent Supply Chain program
    • Explain how the Intel® Transparent Supply Chain program works
    • Discuss the benefits of the Intel® Transparent Supply Chain program to Lenovo customers
    • Explain how to add Intel® Transparent Supply Chain program feature to an order

    Published: 2024-01-29
    Length: 12 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1230
  4. Family Portfolio: Storage Controller Options
    2024-01-23 | 25 minutes | Employees and Partners
    Details
    Family Portfolio: Storage Controller Options

    This course covers the storage controller options available for use in Lenovo servers. The classes of storage controller are discussed, along with a discussion of where they are used, and which to choose.

    After completing this course, you will be able to:
    • Describe the classes of storage controllers
    • Discuss where each controller class is used
    • Describe the available options in each controller class

    Published: 2024-01-23
    Length: 25 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1111
  5. Lenovo-Intel Sustainable Solutions QH
    2024-01-22 | 10 minutes | Employees and Partners
    Details
    Lenovo-Intel Sustainable Solutions QH

    This Quick Hit explains how Lenovo and Intel are committed to sustainability, and introduces the Lenovo-Intel joint sustainability campaign. You will learn how to use this campaign to show customers what that level of commitment entails, how to use the campaign's unsolicited proposal approach, and how to use the campaign as a conversation starter which may lead to increased sales.

    Published: 2024-01-22
    Length: 10 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2524a
  6. Family Introduction: Rack and Tower
    2024-01-19 | 11 minutes | Employees and Partners
    Details
    Family Introduction: Rack and Tower

    This course is designed to give Lenovo sales and partner representatives a foundation on the characteristics of the rack and tower server family. As an introduction to the family, this course also includes positioning, when to use a product, and keywords a client may use when discussing a rack product.

    Course Objectives:
    • Family Characteristics
    • Priority Positioning
    • Product Usage
    • Keywords and Phrases

    Published: 2024-01-19
    Length: 11 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1100r3
  7. FY24Q3 Intel Servers Update
    2023-12-11 | 15 minutes | Employees and Partners
    Details
    FY24Q3 Intel Servers Update

    This update is designed to help you discuss the features and customer benefits of Lenovo servers that use the 5th Gen Intel® Xeon® processors. Lenovo has also introduced a new server, the ThinkSystem SD650-N V3, which expands the supercomputer server family. Reasons to call your customer and talk about refreshing their infrastructure are also included as a guideline.

    Published: 2023-12-11
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2522a
  8. Lenovo Data Center Product Portfolio
    2023-07-21 | 15 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2023-07-21
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1110r6
  9. Family Portfolio: ThinkSystem AMD Rackmount Servers
    2023-06-07 | 15 minutes | Employees and Partners
    Details
    Family Portfolio: ThinkSystem AMD Rackmount Servers

    This course adds AI capability information, specifically Lenovo OVX 3.0, about AMD rackmount servers. After completing this course, you will be able to identify products and features within the ThinkSystem AMD rack server family, describe unique innovations that this product family uses, and recognize when a specific product should be selected. You will also be able to describe how AMD rackmount servers are used in AI environments.

    Published: 2023-06-07
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1216r6
  10. Partner Technical Webinar - Data Center Limits and ISG TAA Compliance
    2023-05-16 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Data Center Limits and ISG TAA Compliance

    In this 60-minute replay, we had two topics. First Vinod Kamath, Lenovo Distinguished Engineer for Data Center Cooling presented on the Systems Configuration and Data Center Ambient Limits. Second, Shama Patari, Lenovo Trade Council, and Glenn Johnson, Lenovo Principal Engineer for Supply Chain presented on ISG TAA Compliance.

    Published: 2023-05-16
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 051223
  11. Lenovo Sustainable Computing
    2022-09-16 | 4 minutes | Employees and Partners
    Details
    Lenovo Sustainable Computing

    This Quick Hit describes the Lenovo sustainable computing program, and the many ways in which Lenovo strives to respect and protect the environment.

    Published: 2022-09-16
    Length: 4 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2504a

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
Bootable Media Creator
Lenovo Services
RackSwitch
ServerProven®
System x®
ThinkSystem®
TopSeller
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, ActiveX®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

SPECpower® is a trademark of the Standard Performance Evaluation Corporation (SPEC).

Other company, product, or service names may be trademarks or service marks of others.