Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter

Product Guide

Home
Top
Author
Updated
31 Oct 2023
Form Number
LP0785
PDF size
14 pages, 250 KB

Abstract

The ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter is a flexible follow-on to the X710 10Gb adapters and is best suited for existing 10Gb customers where they need to maintain 10Gb network support plus provide the investment protection of supporting 25GbE network speeds. By providing unmatched features for server and network virtualization, small packet performance, and low power; the data center network is flexible, scalable, and resilient.

This product guide provides essential presales information to understand the XXV710 adapter and its key features, specifications and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about XXV710 and consider its use in IT solutions.

Change History

Changes in the October 31, 2023 update:

Introduction

The ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter is a flexible follow-on to the X710 10Gb adapters and is best suited for existing 10Gb customers where they need to maintain 10Gb network support plus provide the investment protection of supporting 25GbE network speeds. By providing unmatched features for server and network virtualization, small packet performance, and low power; the data center network is flexible, scalable, and resilient.

The following figure shows the ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter.

ThinkSystem Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter
Figure 1. ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter

Did you know?

The Intel XXV710 adapter offers excellent small packet performance, and offers virtualization features with support for GENEVE, VXLAN, NVGRE offloads, DPDK, SR-IOV, and VMDq protocols.

Part number information

The following table provides the ordering part numbers and feature codes for the Intel XXV710 adapters.

Table 1. Ordering information
Part number Feature code Description
7XC7A05523 B0WY ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter

The ThinkSystem and System x adapter option part numbers includes the following items:

  • One Intel Ethernet adapter
  • Full-height (3U) bracket attached with low-profile (2U) bracket included in the box
  • Documentation

Note: The adapters ship without any SFP28 transceivers or direct attach cables. These items must be ordered separately as listed in the following section.

Supported transceivers and cables

The Intel XXV710 adapters have empty SFP28 cages for connectivity. The adapter either supports connections to a 10 Gb or 25 Gb switch or can share a connection to a 100 Gb switch using a 4:1 breakout cable.

The following table lists the supported transceivers.

Table 2. Transceivers
Part number Feature code Description
1Gb Transceivers
00FE333 A5DL SFP 1000Base-T (RJ-45) Transceiver
10Gb Transceivers
00FE331 B0RJ 10GBASE-LR SFP+Transceiver
49Y4216 0069 Brocade 10Gb SFP+ SR Optical Transceiver
49Y4218 0064 QLogic 10Gb SFP+ SR Optical Transceiver
90Y9412 A1PM SFP+ LR Transceiver
46C3447 5053 SFP+ SR Transceiver
4TC7A78615 BNDR ThinkSystem Accelink 10G SR SFP+ Ethernet transceiver
25Gb Transceivers
4M27A67041 BFH2 Lenovo 25Gb SR SFP28 Ethernet Transceiver
7G17A03537 AV1B Lenovo Dual Rate 10G/25G SR SFP28 Transceiver
4TC7A88638 BYBJ ThinkSystem Finisar Dual Rate 10G/25G SR SFP28 Transceiver

25Gb transceivers: When installed in the Intel XXV710 Ethernet adapter, the supported 25Gb transceiver will currently only operate at 25Gb/s speeds.

The following table lists the supported fiber optic cables and Active Optical Cables.

Table 3. Optical cables
Part number Feature code Description
LC-LC OM3 Fiber Optic Cables (these cables require a 10 GbE SFP+ SR or 25 GbE SFP28 SR transceiver)
00MN499 ASR5 Lenovo 0.5m LC-LC OM3 MMF Cable
00MN502 ASR6 Lenovo 1m LC-LC OM3 MMF Cable
00MN505 ASR7 Lenovo 3m LC-LC OM3 MMF Cable
00MN508 ASR8 Lenovo 5m LC-LC OM3 MMF Cable
00MN511 ASR9 Lenovo 10m LC-LC OM3 MMF Cable
00MN514 ASRA Lenovo 15m LC-LC OM3 MMF Cable
00MN517 ASRB Lenovo 25m LC-LC OM3 MMF Cable
00MN520 ASRC Lenovo 30m LC-LC OM3 MMF Cable
SFP+ 10Gb Active Optical Cables
00YL634 ATYX Lenovo 1m SFP+ to SFP+ Active Optical Cable
00YL637 ATYY Lenovo 3m SFP+ to SFP+ Active Optical Cable
00YL640 ATYZ Lenovo 5m SFP+ to SFP+ Active Optical Cable
00YL643 ATZ0 Lenovo 7m SFP+ to SFP+ Active Optical Cable
00YL646 ATZ1 Lenovo 15m SFP+ to SFP+ Active Optical Cable
00YL649 ATZ2 Lenovo 20m SFP+ to SFP+ Active Optical Cable
OM4 LC to LC Cables (these cables require a transceiver)
4Z57A10845 B2P9 Lenovo 0.5m LC-LC OM4 MMF Cable
4Z57A10846 B2PA Lenovo 1m LC-LC OM4 MMF Cable
4Z57A10847 B2PB Lenovo 3m LC-LC OM4 MMF Cable
4Z57A10848 B2PC Lenovo 5m LC-LC OM4 MMF Cable
4Z57A10849 B2PD Lenovo 10m LC-LC OM4 MMF Cable
4Z57A10850 B2PE Lenovo 15m LC-LC OM4 MMF Cable
4Z57A10851 B2PF Lenovo 25m LC-LC OM4 MMF Cable
4Z57A10852 B2PG Lenovo 30m LC-LC OM4 MMF Cable

The following table lists the supported direct-attach copper (DAC) cables.

Table 4. Copper cables
Part number Feature code Description
SFP+ 10Gb Passive DAC Cables
00D6288 A3RG 0.5m Passive DAC SFP+ Cable
90Y9427 A1PH 1m Passive DAC SFP+ Cable
00AY764 A51N 1.5m Passive DAC SFP+ Cable
00AY765 A51P 2m Passive DAC SFP+ Cable
90Y9430 A1PJ 3m Passive DAC SFP+ Cable
90Y9433 A1PK 5m Passive DAC SFP+ Cable
00D6151 A3RH 7m Passive DAC SFP+ Cable
SFP28 25Gb Passive DAC Cables
7Z57A03557 AV1W Lenovo 1m Passive 25G SFP28 DAC Cable
7Z57A03558 AV1X Lenovo 3m Passive 25G SFP28 DAC Cable
7Z57A03559 AV1Y Lenovo 5m Passive 25G SFP28 DAC Cable
QSFP28 100G-to-4x25G Ethernet Breakout Cables
7Z57A03564 AV22 Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
4Z57A85043 BS32 Lenovo 1.5m 100G to 4x25G Breakout SFP28 Breakout DAC Cable
4Z57A85044 BS33 Lenovo 2m 100G to 4x25G Breakout SFP28 Breakout DAC Cable
7Z57A03565 AV23 Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03566 AV24 Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable

Features

The Intel XXV710 adapter is optimized for data center, cloud, and mobile applications and include the following features:

  • Compliance with the IEEE 802.3by and 25GEthernet.org 25 GbE specifications
  • VXLAN, NVGRE and GENEVE Hardware Offloads: These stateless offloads preserve application performance for overlay networks. With these offloads, it is possible to distribute network traffic across CPU cores. At the same time, X710 offloads LSO, GSO, and checksum from the host software, which reduces CPU overhead.
  • Mobile and cloud application acceleration: Intel’s Data Plan Development Kit (DPDK) delivers an open driver where users can fine-tune small packet performance.
  • Low latency: Intel Ethernet Flow Director delivers hardware-based application steering and Intel Data Direct I/O makes the processor cache the primary destination and source of I/O data rather than main memory. Combined, latency is reduced and Intel reports a three-fold improvement in RPS.
  • Virtualization performance: With Intel Virtualization Technology (VT), the X710 family of adapters delivers outstanding I/O performance in virtualized server environments. These adapters reduce I/O bottlenecks by providing intelligent offloads for networking traffic per virtual machine (VM), which enables near-line rate speeds for small packets and supports almost an unlimited amount of isolated traffic flows so that you can scale your cloud environment.
  • Next-generation VMDq: The X710 adapters support up to 256 VMDq VMs and offer enhanced Quality of Service (QoS) feature by providing weighted round-robin servicing for the Tx data. The adapters offload the data-sorting functionality from the hypervisor to the network silicon, which improves data throughput and CPU usage.
  • PCI-SIG SR-IOV implementation: Provides an implementation of the PCI-SIG standard for I/O Virtualization. The physical configuration of each port is divided into multiple virtual ports. Each virtual port is assigned to an individual VM directly by bypassing the virtual switch in the Hypervisor, which results in near-native performance.
  • VM load balancing: Provides traffic load balancing (Tx and Rx) across VMs that are bound to the team interface. It also provides fault tolerance if a switch, port, cable, or adapter fails.

Specifications

The Intel XXV710 adapter has the following specifications:

  • Empty SFP28 cages for supported transceivers or DAC cables
  • Host interface:
    • PCI Express 3.0; x8
    • PCI Power Management/ACPI Extensions
    • MSI-X Support
    • Energy Efficient Ethernet
    • 1,536 Tx and Rx queues
  • Virtualization features:
    • Microsoft Network Virtualization that uses Generic Routing Encapsulation (NVGRE)
    • VMware Virtual Extensible LAN (VXLAN)
    • GENEVE support
    • VMDq for intelligent offloads
    • SR-IOV direct assignment support
    • Virtual Bridging Support: VEPA/802.1Qbg, BPE/802.1Qbh
    • Virtual Functions: Up to 128 per device (SR-IOV)
    • Hardware Queue Pairs: Up to 1.5K
  • Management features:
    • Advanced filtering capabilities (IPv4, IPv6)
    • SNMP
    • RMON statistic counters
  • Additional features:
    • Jumbo Frame Support: 9728 bytes
    • VLAN support
    • Flow Control
    • IEEE 1588 Time Synchronization Support (802.1as)
  • TCP/IP Layer 2 features:
    • Receive Side Scaling (RSS)
    • Large Send Offload (LSO)
    • TCP/UDP/IP/SCTP Checksum Offload
    • IPv4, IPv6
    • Supports iSCSI as an iSCSI software initiator
  • IEEE 802.1Q VLAN support with VLAN tag insertion, with stripping and packet filtering for up to 4096 VLAN tags.
  • IEEE 802.3x flow control support.
  • IEEE 802.1p Class of Service (CoS)/QoS.
  • Support for Advanced Packet Filtering.
  • Teaming support:
    • Adapter Fault Tolerance (AFT)
    • Switch Fault Tolerance (SFT)
    • Adaptive Load Balancing (ALB)
    • VM Load Balancing (VMLB)
    • IEEE 802.3ad (link aggregation control protocol)
  • Intel PROSet Utility for easy configuration and management.
  • UEFI and legacy PXE boot
  • Compliant with the European Union RoHS directive 2011/65/EU to reduce the use of hazardous materials.

Standards supported

The Intel XXV710 support the following IEEE standards:

  • IEEE 802.3by 25 Gb/s Ethernet Standard
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.1p CoS traffic prioritization
  • IEEE 802.1Q VLAN tagging
  • IEEE 802.3ad Link Aggregation Control Protocol
  • IEEE 802.3x Full-duplex flow control
  • IEEE 802.3bd priority-based flow control
  • IEEE 1588, IEEE 802.1AS time sync
  • IEEE 802.3az Energy Efficient Ethernet

Server support

The following tables list the ThinkSystem servers that are compatible.

Table 5. Server support (Part 1 of 4)
Part Number Description 2S AMD V3 2S Intel V3 4S 8S Intel V3 Multi Node GPU Rich 1S V3
SR635 V3 (7D9H / 7D9G)
SR655 V3 (7D9F / 7D9E)
SR645 V3 (7D9D / 7D9C)
SR665 V3 (7D9B / 7D9A)
ST650 V3 (7D7B / 7D7A)
SR630 V3 (7D72 / 7D73)
SR650 V3 (7D75 / 7D76)
SR850 V3 (7D97 / 7D96)
SR860 V3 (7D94 / 7D93)
SR950 V3 (7DC5 / 7DC4)
SD535 V3 (7DD8 / 7DD1)
SD530 V3 (7DDA / 7DD3)
SD550 V3 (7DD9 / 7DD2)
SR670 V2 (7Z22 / 7Z23)
SR675 V3 (7D9Q / 7D9R)
ST250 V3 (7DCF / 7DCE)
SR250 V3 (7DCM / 7DCL)
7XC7A05523 ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter N N N N N N N N N N N N N N N N N
Table 6. Server support (Part 2 of 4)
Part Number Description Edge Super Computing 1S Intel V2 2S Intel V2
SE350 (7Z46 / 7D1X)
SE350 V2 (7DA9)
SE360 V2 (7DAM)
SE450 (7D8T)
SE455 V3 (7DBY)
SD665 V3 (7D9P)
SD665-N V3 (7DAZ)
SD650 V3 (7D7M)
SD650-I V3 (7D7L)
SD650-N V3 (7D7N)
ST50 V2 (7D8K / 7D8J)
ST250 V2 (7D8G / 7D8F)
SR250 V2 (7D7R / 7D7Q)
ST650 V2 (7Z75 / 7Z74)
SR630 V2 (7Z70 / 7Z71)
SR650 V2 (7Z72 / 7Z73)
7XC7A05523 ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter N N N Y N N N N N N N N N N N N
Table 7. Server support (Part 3 of 4)
Part Number Description AMD V1 Dense V2 4S V2 8S 4S V1 1S Intel V1
SR635 (7Y98 / 7Y99)
SR655 (7Y00 / 7Z01)
SR655 Client OS
SR645 (7D2Y / 7D2X)
SR665 (7D2W / 7D2V)
SD630 V2 (7D1K)
SD650 V2 (7D1M)
SD650-N V2 (7D1N)
SN550 V2 (7Z69)
SR850 V2 (7D31 / 7D32)
SR860 V2 (7Z59 / 7Z60)
SR950 (7X11 / 7X12)
SR850 (7X18 / 7X19)
SR850P (7D2F / 2D2G)
SR860 (7X69 / 7X70)
ST50 (7Y48 / 7Y50)
ST250 (7Y45 / 7Y46)
SR150 (7Y54)
SR250 (7Y52 / 7Y51)
7XC7A05523 ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter N N N N N N N N N N N Y Y Y Y N Y N Y
Table 8. Server support (Part 4 of 4)
Part Number Description 2S Intel V1 Dense V1
ST550 (7X09 / 7X10)
SR530 (7X07 / 7X08)
SR550 (7X03 / 7X04)
SR570 (7Y02 / 7Y03)
SR590 (7X98 / 7X99)
SR630 (7X01 / 7X02)
SR650 (7X05 / 7X06)
SR670 (7Y36 / 7Y37)
SD530 (7X21)
SD650 (7X58)
SN550 (7X16)
SN850 (7X15)
7XC7A05523 ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter Y N N N N Y Y N Y N N N

Operating system support

The following table lists the supported operating systems for the adapter.

Tip: This table is automatically generated based on data from Lenovo ServerProven.

Table 9. Operating system support for ThinkSystem Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter, 7XC7A05523
Operating systems
SE450
SR250
ST250
SD530 (Xeon Gen 2)
SR630 (Xeon Gen 2)
SR650 (Xeon Gen 2)
SR850 (Xeon Gen 2)
SR850P (Xeon Gen 2)
SR860 (Xeon Gen 2)
SR950 (Xeon Gen 2)
ST550 (Xeon Gen 2)
SD530 (Xeon Gen 1)
SR630 (Xeon Gen 1)
SR650 (Xeon Gen 1)
SR850 (Xeon Gen 1)
SR860 (Xeon Gen 1)
SR950 (Xeon Gen 1)
ST550 (Xeon Gen 1)
Microsoft Windows Server 2012 R2 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
Microsoft Windows Server 2016 N Y Y Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
Microsoft Windows Server 2019 Y Y Y Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
Microsoft Windows Server 2022 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server version 1709 N N N N N N N N N N N Y Y Y N Y 1 Y Y
Microsoft Windows Server version 1803 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y N
Red Hat Enterprise Linux 6.10 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 6.9 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 7.3 N N N N N N N N N N N Y Y Y Y 1 N Y Y
Red Hat Enterprise Linux 7.4 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 7.5 N Y Y N N N N N N N N Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 7.6 N N N Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 7.7 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.8 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.9 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.0 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y 1 Y 1 Y Y
Red Hat Enterprise Linux 8.1 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.2 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.3 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.5 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.6 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.7 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.8 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.9 Y Y Y Y Y Y Y Y Y Y Y N N N N N N N
Red Hat Enterprise Linux 9.0 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.3 Y Y Y Y Y Y Y Y Y Y Y N N N N N N N
SUSE Linux Enterprise Server 11 SP4 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 11 SP4 with Xen N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 12 SP2 N N N N N N N N N N N Y Y Y Y 1 N Y Y
SUSE Linux Enterprise Server 12 SP2 with Xen N N N N N N N N N N N Y Y Y Y 1 N Y Y
SUSE Linux Enterprise Server 12 SP3 N Y Y N N N N Y N N N Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 12 SP3 with Xen N Y Y N N N N Y N N N Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 12 SP4 N N N Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 12 SP4 with Xen N N N Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 12 SP5 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 with Xen N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 N Y Y Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 15 SP1 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 15 SP1 with Xen N Y Y Y Y Y Y Y Y Y Y Y Y Y Y 1 Y 1 Y Y
SUSE Linux Enterprise Server 15 SP2 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 with Xen N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 with Xen N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 with Xen N Y Y Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.0 U3 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.5 N N N N N N N N N N N Y Y Y N N Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U1 N N N N N N N N N N N Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U2 N Y Y Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U3 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 N Y Y N N N N N N N N Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U1 N N N Y Y Y Y 1 Y Y 1 Y Y Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U2 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y 1 Y 1 Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U3 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U1 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U2 N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U3 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

1 The maximum quantity of Intel X710-DA2 plus XXV710-DA2 adapters supported is 5. Detail information please refer to Support Tip HT508158

Physical specifications

The Intel XXV710-DA2 adapter has the following dimensions:

  • Length: 168 mm (6.6 in.)
  • Width: 69 mm (2.7 in.)
  • Height: 15 mm (0.6 in.)

Operating environment

The XXV710 adapters are supported in the following environment:

  • Operating temperature: 0 to 55 °C (32 to 131 °F)
  • Storage temperature: -20 to 65 °C (-4 to 149 °F)
  • Shipping conditions: -20 to 70 °C (-4 to 158 °F)
  • Air flow requirement (LFM)
    • 25G optics: 200 LFM
    • Direct-attach 25G cables: 100 LFM
  • Wet bulb (max): 27 °C
  • Relative humidity (non-operating): 10% to 90%
  • Maximum dew Point (operating): 21 °C
  • Maximum operating altitude: 7,000 feet or 2,134 meters
  • Vibration and shock with 25-GS0009 standard
  • Electrostatic/electromagnetic susceptibility with 25-GS0009 standard

Warranty

One-year limited warranty. When installed in a supported server, these adapters assume the server’s base warranty and any warranty upgrade.

Agency approvals

The adapter conforms to the following standards:

  • EN55032
  • EN55024
  • EN 61000-3-2
  • EN 61000-3-3
  • ICES-003, Issue-004
  • FCC 47 CFR Part 15 Class A
  • Japan VCCI
  • AS/NZS CISPR 22 / C-tick
  • RRL for KC
  • BSMI
  • UL 94 V-1

Top-of-rack Ethernet switches

The following table lists the 10 Gb, 25 Gb and 100 Gb Ethernet LAN switches that are offered by Lenovo.

Table 10. Ethernet LAN switches
Part number Description
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
7159G64 Lenovo RackSwitch G8264 (Rear to Front)
7159DRX Lenovo RackSwitch G8264CS (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)

For more information, see the list of Product Guides in the following switch categories:

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
RackSwitch
ServerProven®
System x®
ThinkSystem®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.